ELECTRICAL DATA FOR THE USE OF CERTIFIED LICENSED ELECTRICIAN
WARNING: Shock Hazard! Under No Circumstances Should This Spa Be Installed By Anyone
Other Than A Certified Licensed Electrician!
All wiring MUST be in accordance with the National Electrical Code and all local codes.
• Terminal Block Torque field connections should be between 21 and 23 inch lbs.
• Readily accessible disconnecting means to be provided at time of installation.
• Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter “G.F.C.I.” mounted at least 6 feet (1.8m)
from the inside walls of the spa and in line of sight from the equipment compartment.
• Remove white wire from J11 to J32 and move key #10 to Off position for 40 amp configuration.
CONVERSION
OF
HILO
AND
SANTO
FROM
120V
TO
240V
120V Power Connection
Hilo and Santo
1 Test Mode (normally off)
2 Pump Time Out
In “ON” position, Pump turns off after 30 minutes
In “OFF” position, Pump turns off after 15 minutes
3 Panel Option (must be OFF)
In “ON” position, enables mini panel
In “OFF” position, enables current panel
4 Aux Freeze (must be OFF)
5 Panel Button Layout (must be OFF)
In “ON” position, enables J/L/-/+/w/BLW/AUX
In “OFF” position, enables B/J/T/L or J/T/L
6 Frequency (must be OFF)
In “ON” position, 50Hz operation
In “OFF” position, 60Hz operation
7 Mode Changes (must be OFF)
In “ON” position, standard mode only
In “OFF” position, enables standard/economy/sleep
8 Temperature Display
In “ON” position, temperature is displayed in degrees Celsius
In “OFF” position, temperature is displayed in degrees Fahrenheit
9 Blower / Pump 2 Enable
In “ON” position, enables pump 2
In “OFF” position, disables pump 2
10 Amperage Setting
In “ON” position, for Low Amp service
In “OFF” position, for High Amp service
DIP SWITCH KEY
A grounding lug has been provided on the exterior of the pack chassis to allow connection
of a ground wire to a local grounding point to be establish in compliance with the National
Electric Code (NEC) and all local codes.
240V Power Connection
Hilo and Santo
9