Leister ALLIED VARIMAT V2 Скачать руководство пользователя страница 2

18

How do I start the automatic hot-air welding machine VARIMAT V2 ?

1.  Connect power supply cord to the line/mains 
2. 

Main switch (3) 

ON 

ON

3.  Press Drive button 

 Turn e-Drive 

4.  Press Heating button 

 Turn e-Drive 

5.  Press e-Drive 

 Heating up time approx. 3 – 5 minutes 

 

6.   Carry out a test weld according to the welding instruction of the material manufacturer 

and national standards or guidelines. Approve test weld.

7. Welding 

How do I switch off the automatic hot-air welding machine VARIMAT V2 ?

1.  Press e-Drive 

 (Fig. 1).

2.  Press «

Cool down OK

» e-Drive 

 and allow to cool approx. 4 minu-

tes (Fig. 2). Blower switches off automatically.

3. After 

welding nozzle (9)

 has cooled down, 

main switch (3)

 OFF 

OFF

Congratulations on purchasing an automatic hot-air welding machine VARIMAT V2 !

You have chosen a top-class automatic hot-air welding machine made of high-quality materials. 
This device has been developed and produced according to the latest welding technologies.
Every VARIMAT V2 passes stringent quality checks before leaving the factory in Switzerland.

Table of contents

Quick info 

 

Page   18

Application, warning, caution  

 

Page   19

Conformity, disposal, technical data    

Page   20

Description of device, controls  

 

Page   21

Transport 

 

Page   22

Joining force, operating preparation, drive sensor adjustment 

Page   23

Device positioning, welding procedure  

Page   24

Button combinations 

 

Page   25

Work mode (chapter 1) 

1.1   Setpoint display 

Page   25

   

1.2   Work display 

Page   26

   

1.3   Setting the drive speed 

 

 

   

1.4   Setting the welding temperature  

Page   27

   

1.5   Setting the air volume 

 

 

   

1.6   Length measurement, blower and drive counter 

Page    28

   

1.7   Selecting profiles 

 

 

   

1.8   Cooling down 

Page   29

   

1.9   Standby 

 

 

   

1.10 Error messages  

Page   30

Profil setup (chapter 2) 

2.1   Creating profiles 

Page   30 

   

2.2   Standby setup 

Page   31

FAQ 

 

Page   31

Types of Leister VARIMAT V2, accessories, training, maintenance, service and repair, warranty 

Page   32

Quick info

(Fig. 1)

(Fig. 2)

GB

USA

Содержание ALLIED VARIMAT V2

Страница 1: ...VARIMAT V2 Leister Technologies AG Galileo Strasse 10 CH 6056 Kaegiswil Switzerland Tel 41 41 662 74 74 Fax 41 41 662 74 16 www leister com sales leister com...

Страница 2: ...rials This device has been developed and produced according to the latest welding technologies Every VARIMAT V2 passes stringent quality checks before leaving the factory in Switzerland Table of conte...

Страница 3: ...ice Warning Connect tool to a receptacle with protective earth terminal Any interruption of the protective earth conductor inside or outside the tool is dangerous Use only extension cables cords with...

Страница 4: ...LpA dB 70 LpA dB 70 Weight kg 35 lbs 77 without power supply cord Dimensions L W H mm 650 430 330 inch 25 17 13 Mark of conformity 2 Protection class I 1 Technical data and specifications are subject...

Страница 5: ...16 5 4 10 11 17 9 8 12 14 18 19 20 21 22 23 24 25 26 28 31 33 25 Cheese head screw 26 Lower guide bar 27 Upper guide bar 28 Clamping lever upper guide bar 29 Holder for power supply cord 30 Round belt...

Страница 6: ...ping screw lower guide bar 31 and move guide bar 27 into transport position tighten clamping screw lower guide bar 31 Close carrying case at sides Close carrying case at top Transport For transporting...

Страница 7: ...nto the required position using clamping screw lower guide bar 31 and upper guide bar 27 using clamping lever upper guide bar 28 Clip strain relief of power supply cord 1 in holder 29 Check the basic...

Страница 8: ...ding work use e Drive press 2 x to switch off heating In this way the welding nozzle 9 is cooled down and the blower automatically switches off after approx 4 minutes section 1 8 Cooling down Turn off...

Страница 9: ...rs If however the heating element temperature is higher than 80 C when switching on the display will immediately change to the Cool down mode section 1 8 Cooling down in which the blower is always ope...

Страница 10: ...entage indication changes with the symbol The welding result can be affected depending on the undervoltage overvoltage If no button is pressed after a definite time welding nozzle 9 NOT in welding pos...

Страница 11: ...and drive counter You can change to the relevant menu by pressing the Heating or Blower button 1 4 Setting the welding temperature The welding temperature can be changed with the Heating button The we...

Страница 12: ...down You can change to the relevant menu using the Drive button or Heating button 1 6 Length measurement blower and drive counter This menu Fig 4 appears if the Drive button is pressed for at least 3...

Страница 13: ...d Perform a test welding according to the welding instructions of the material manufacturer and the national standards or guidelines Approve the test welding 1 Work mode 1 8 Cooling down If the symbol...

Страница 14: ...hed in Standby mode the display will change back to the initial state For setting the standby time section 2 2 Standby setup 1 Work mode 1 10 Error message If a malfunction occurs in the automatic hot...

Страница 15: ...perating preparation page 23 The set welding temperature is not reached The air volume is set too high Insufficient voltage Startup mechanism not working Adjust drive sensor see page 23 Device does no...

Страница 16: ...ve counter reaches 400 h or the blower counter reaches 2000 h the message Maintenance servicing will appear on the display the next time the main switch 3 is switched on This message is displayed for...

Страница 17: ...tzerland Tel 41 41 662 74 74 Fax 41 41 662 74 16 www leister com sales leister com Copyright by Leister BA VARIMAT V2 08 2009 07 2020 Art 137 889 part 1 Allied Power Tools 12 76 Rushdale St Knoxfield...

Отзывы: