Leine Linde ADS Classic Скачать руководство пользователя страница 5

RS-232 communication

The analysis software is supplied with connection cabling with which a PC 
is connected to the encoder through the serial port. We recommend that PC 
communication should not be connected during operation.

If the encoder is supplied 
with cabling, we recommend 
that the connection to the PC 
should be effected via a D-SUB 
connector (9-pole female), for 
example in a terminal box in 
accordance with Figure G.

 

Cable colour 

Function 

Pin D-sub

 

Grey / Pink 

Rxd 

 

3

 

Red / Blue 

Txd 

 

2

 Blue 

  5

 

 

Connected to one another   

4

 

 

 

 

6

 

 

 

 

8

A standard extension cable, 9-pole D-sub male to 9-pole D-sub female, can be 
used between the PC and the above connection.
Note that the length between the encoder and the PC must not exceed 10 m.

ADS PC SOFTWARE

A PC program with which information from the encoder about the operating 
conditions and any faults can be received is provided for communication 
with the ADS encoder. Your PC is connected to the encoder via the serial port 
using the special cable supplied or a standard RS-232 cable in accordance 
with the example in the Installation Specifi cation. Communication takes 
place with an RS-232 interface. Note that the maximum cable length 
between the encoder and the PC is 10 m.

Content

 

•  Diskette with PC software. Part No. 01290021

 

•  Manual Advanced Diagnostic System.

 

•  RS-232 cable 9-pole D-sub female – connector to the encoder. 

 

  Part No. 01209083

ADS encoder

Coupling Box

RS 232 communication

Incremental signals

Figure G

System requirements

 

•  PC with at least a 486 processor.

 

•  Windows 95, 98 or NT.

Installation

1.  Insert the diskette in the diskette drive.
2.  Select the diskette drive in the Program Manager.
3.  Start the fi le..\setup.exe
4.  Follow the instructions.

Confi guration of software

1. Start \Diagnostik.exe
 Select 

settings.

 

See Figure H.

2.  Set the COM port that you are using.
 

Set the frequency with which you require the information to be updated  

 

for repeated updating.

 

Indicate the language that you wish to use, Swedish or English.

 

It is also possible to communicate via a modem installed in Windows and  

 

an RS-232 modem via the telephone line. The software then calls the 

 

indicated telephone number and starts the communication when the    

 

”Online” key is pressed. We recommend a maximum updating speed of 

 

1.0 s when a modem is in use.

 

See Figure I.

Figure H

Figure I

6

7

Содержание ADS Classic

Страница 1: ...peci cations in this manual can be changed without prior notice Leine Linde AB T 46 152 265 00 F 46 152 265 05 Box 8 SE 645 21 Str ngn s Sweden www leinelinde com info leinelinde se ADS Classic Advanc...

Страница 2: ...sembly 3 Disassembly 4 Electrical connection 4 Alarm output 5 RS 232 communication 6 ADS PC SOFTWARE 6 System requirements 7 Installation of software 7 Con guration of software 7 Receiving information...

Страница 3: ...potential and to protect the encoder in this way against ESD discharges which may damage the encoder Incremental encoders of model 861 are designed for assembly directly on the drive shaft with a tor...

Страница 4: ...so shown on the encoder label Speci cation of screw terminal block Cable cross section 0 14 1 5 mm or AWG 26 16 Wire end sleeve cross section 0 25 1 mm Stripping length 6 mm Tightening torque 0 5 0 6...

Страница 5: ...e example in the Installation Speci cation Communication takes place with an RS 232 interface Note that the maximum cable length between the encoder and the PC is 10 m Content Diskette with PC softwar...

Страница 6: ...emperature when the fault is rst detected The same fault is stored only on a single occasion unless another fault is stored subsequently Suf cient memory capacity is available for the storage of 13 fa...

Страница 7: ...ate normally internally but the signal that is sent out from the encoder will not be correct or will be absent External incremental signals are not checked at a signal frequency higher than 40 kHz sin...

Отзывы: