Leica Sprinter 50 Скачать руководство пользователя страница 6

3

Instrument Components

Sprinter 50 - 1.0.0en

EN
DE
FR
ES

NO
SV
FI
DA

IT
PT
NL

2. Instrument Components

Container Contents 

Sprinter, batteries (4x), allen key, user manual, error 

and operation messages leaflet, strap.

Accessories

Tripod, aluminum staff (region dependant). (Optional: 

sunshade, 4 rechargeable batteries and charger.)

3. Measurement Preparations

3.1 Change battery

Insert 4 AA dry cells according to the positive and 

negative signs as indicated on the holder. 

)

Always replace with a complete battery set!

)

Do not use old and new batteries together.

)

Do not use batteries from different manufac-

turers or batteries of different types.

3.2 Set-up instrument

Levelling

• Set up the tripod. Extend the legs to a suitable 

length and ensure that the tripod head is approxi-

mately level. Tread the tripod shoes firmly into the 

ground to ensure stability. 

• Mount the instrument on the tripod by screwing the 

tripod screw onto the base of the instrument. 

• Use the three levelling foot screws to center the 

circular bubble in order to level the instrument.

a) Horizontal fine motion 

screw

b) Battery compartment

c) Circular level

d) Gunsight

e) Focusing knob

f) Handle

g) Eyepiece

h) LCD display

i) Base plate

j) Levelling footscrew

a

j

i

h

g

f

e

d

b
c

Sprinter 01

Содержание Sprinter 50

Страница 1: ...Sprinter_01 Sprinter 50 User Manual Version 1 0 EN DE FR ES IT PT NL NO SV FI DA...

Страница 2: ......

Страница 3: ...nual Gebrauchsanweisung Manuel d utilisation Manual del usuario Manuale d uso Manual de Opera o Gebruiksaanwijzing Brukerh ndbok Handbok K ytt j n k sikirja Brugervejledning EN DE FR ES NO SV FI DA IT...

Страница 4: ...duct Product identification The model and the serial number of your product are indicated on the type plate Enter the model and serial number in your manual and always refer to this information when y...

Страница 5: ...ON Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor or moderate injury and or appreciable mate rial financial and environmental damage Importan...

Страница 6: ...and new batteries together Do not use batteries from different manufac turers or batteries of different types 3 2 Set up instrument Levelling Set up the tripod Extend the legs to a suitable length and...

Страница 7: ...cal hints First check and adjust the electronic and optical line of sight errors then the circular level on the instrument and then the staff before starting work in the field after long storage perio...

Страница 8: ...stment program b a Measurement Mode Adjustment Mode Battery icon at various capacities Measured staff height Measured distance MEAS ADJ Key Symbol 1st level functions 2nd level functions a On Off Powe...

Страница 9: ...te measurement 5 1 Height and Distance Mea surement Measurement Standby Mode Measuring in progress Measurement with height and distance Step Key Description 1 Press to switch on the instru ment Leica...

Страница 10: ...conds to accept Now shift the Sprinter towards staff A and set it up at about 3 m to staff A Step 3 Aim at Staff B and press MEAS key Measure ment display press and hold measuring key for 3 seconds to...

Страница 11: ...ollimation needs to be adjusted Step Description 1 Level instrument 2 Turn instrument by 180 3 Center bubble if it extends beyond the centering circle 4 Correct half of the error with the Allen key Re...

Страница 12: ...argeting E106 Out Of Level Level the instrument E108 Data File Error Data file error E110 Target Too Close Move staff or instrument further apart E111 Target Too far Move staff or instrument closer to...

Страница 13: ...l in normal position Collimation is out of correction range E119 Staff Blocked Not enough barcode length for measurement E120 Image sensor Error Contact services E121 Adjustment Inverse Staff Not Allo...

Страница 14: ...tect against shock and vibration Shipping transport of batteries When transporting or shipping batteries the person in charge of the product must ensure that the applicable national and international...

Страница 15: ...icipate and avoid oper ational hazards The person responsible for the product must ensure that all users understand these directions and adhere to them 10 2 Intended Use Permitted use Electronic and o...

Страница 16: ...onsible for supplying the product including the user manual and original accessories in a completely safe condi tion Manufacturers of non Leica Geosystems acces sories The manufacturers of non Leica G...

Страница 17: ...ence Agreement Such agreement is provided together with all products and can also be found at the Leica Geosystems home page at http www leica geosystems com swlicense or your Leica Geosystems dealer...

Страница 18: ...onment first contact the safety authorities responsible for the electrical installations and follow their instructions CAUTION Strong magnetic fields in the immediate vicinity e g transformers melting...

Страница 19: ...ple may sustain injury Precautions When setting up the product make sure that the accessories are correctly adapted fitted secured and locked in position Avoid subjecting the product to mechanical str...

Страница 20: ...to constitute a fire hazard Precautions Before shipping the product or disposing of it discharge the batteries by running the product until they are flat When transporting or shipping batteries the p...

Страница 21: ...uct appropriately in accordance with the national regulations in force in your country Always prevent access to the product by unauthorized personnel Product specific treatment and waste management in...

Страница 22: ...nnot completely exclude the possi bility that the product may be disturbed by very intense electromagnetic radiation for example near radio transmitters two way radios or diesel genera tors Precaution...

Страница 23: ...y turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation...

Страница 24: ...range for electronic measurements with standard aluminum barcode staff 2 m to 100 m Optical Shortest focusing distance 50 cm Measuring time single measure Electronic Typically 3 seconds and less in n...

Страница 25: ...ircle of 360 400 gon Graduation and numerals scale reso lution at 1 upper scale and at 50 gon intervals lower scale Side Drive Movement Play in side drive Continuous horizontal dual drive System MMI c...

Страница 26: ...incl front of lens tube to fully extended eyepiece 219 mm Width from the external face of focusing drive to the external side of circular bubble holder 196 mm Height incl hand grip base fully extende...

Отзывы: