2-12
Rugby 55
Basic Operation
2.6
The Elevation Alert (H.I.) Function
)
The elevation alert feature of the Rugby 55 is normally OFF when shipped. It
can be enabled to turn on automatically every time the Rugby is turned on by
using a special procedure found in the Troubleshooting section.
•
The Elevation Alert or Height of Instrument function is designed to prevent
incorrect work caused by sudden movement or settling of the tripod that
would cause the laser to level at a lower height.
•
The Elevation Alert function becomes active and monitors the movement
of the laser 30 second after the unit has completely leveled and the head
starts rotating.
•
The elevation alert monitors the laser and both the X and Y axis LED’s will
begin flashing and the Rugby will beep rapidly if disturbed.
•
To stop the alert turn Rugby off and on again. Check the height of the
instrument before beginning to work again.