Rugby 260SG / 270SG / 280DG, Troubleshooting
45
8.2
Troubleshooting Suggestions
Description
Whenever there are questions regarding your Rugby, check the basics first.
•
Mode of operation: automatic or manual.
•
Battery status.
•
Alert screens: H.I., servo limit, temperature, adjustment.
•
Head speed setting.
•
Beam mask setting.
Symptom
Possible causes and solutions
No beam
Check with a receiver to verify.
No self-leveling
Manual mode, set to automatic mode.
Cannot change
grade
•
Check the other axis.
•
Check operation in manual mode.
•
Check if at grade limit.
Loss of distance
•
Check the window surfaces.
•
Check with a different receiver.
•
At extended distances, decreasing the head speed may
improve performance.
Head rotates
slowly
In low battery mode the Rugby will rotate slowly (7 rps) to trigger
the laser low battery function on the Rod Eye Pro receiver.