background image

Safety instructions

Disposal

CAUTION

Flat batteries must not be disposed of with house-
hold waste. Care for the environment and take
them to the collection points provided in accord-
ance with national or local regulations.

The product must not be disposed with
household waste. Dispose of the product
appropriately in accordance with the national
regulations in force in your country. Adhere
to the national and country specific reg-
ulations.

Product specific treatment and waste man-
agement can be downloaded from our
homepage.

Transport

Transport of instrument

Always set the device in "Locked" position by turn-
ing the lock switch when transporting the device
(see

Levelling lock

). Please use the original case

or an equivalent packaging for transporting and
shipping your measuring device.

Transport of Li-Ion battery

WARNING

During transport, shipping or disposal of batteries
it is possible for inappropriate mechanical influ-
ences to constitute a fire hazard.

Precautions:

Before shipping the product or disposing it, dis-
charge the batteries by running the product until
they are flat. When transporting or shipping bat-
teries, the person in charge of the product must
ensure that the applicable national and inter-
national rules are observed. Before transportation
or shipping, contact your local passenger or
freight transport company.

WARNING

High mechanical stress, high ambient tem-
peratures or immersion into fluids can cause leak-
age, fire or explosion of the batteries.

Precautions:

Protect the batteries from mechanical influences
and high ambient temperatures. Do not drop or
immerse batteries into fluids.

For further information about charging
please refer to

Li-Ion battery.

Leica Lino P5

19

Содержание Lino P5

Страница 1: ...Leica LINO P5...

Страница 2: ...Overview 2 Technical data 3 Instrument Set up 4 Operations 7 How to use the smart adapters 9 Message Codes 11 Accuracy Check 12 Care 15 Warranty 16 Safety instructions 17 Leica Lino P5 1...

Страница 3: ...t right angles It supports you on job side with verticaland hori zontalfive points four points and one point in front of the device which are arranged precisely in 90 to each other 1 Window of plumb u...

Страница 4: ...54 IEC 60529 dust and splash water Drop resistant 6 x 0 5 m 1 64 ft Battery type 3 alkaline AA opt Li Ion battery pack 5200 mAh Operating time with Li Ion battery 59h 5 point 100h 2 point continuous...

Страница 5: ...entially hazardous situation or an unintended use which if not avoided may result in minor injury and or appreciable material financial and environmentaldamage Important paragraphs which must be adher...

Страница 6: ...ter this storage period the batteries must be recharged CAUTION Connecting the charger using the wrong adapter may cause serious damage to the instrument Any damage caused by misuse is not covered by...

Страница 7: ...commend using high quality Alkaline batteries Insert Alkaline batteries Insert Alkaline batteries in the battery pack Insert the battery pack Insert the battery pack by pressing it down and then tilti...

Страница 8: ...locked position see Levelling lock To activate auto power off after 30 min operation press and hold the On button at start for 5 sec The status LED blinks 3 times in green colour To deactivate it agai...

Страница 9: ...Operations Functions Check if self levelling is required and cor respondingly activated See Levelling lock for details Verticaldots horizontaldots on Horizontaldots on Verticaldots on Leica Lino P5 8...

Страница 10: ...r Snap the device on the Twist 360 adapter Alignment of vertical laser lines Turn the device 360 around the plumb point to adjust the verticalline Alignment of horizontal laser lines Turn the adjustme...

Страница 11: ...How to use the smart adapters Different fixing applications Leica Lino P5 10...

Страница 12: ...ut of self levelling range Place the instrument almost hori zontaland self levelling willstart automatically blinks lights red Instrument is out of self levelling range and has low power Charge Li Ion...

Страница 13: ...the line or the point on wall A1 Rotate the instru ment by 180 and mark the horizontallaser line or the laser point in exactly the same way on wall B1 Then place the instrument at the same elevation...

Страница 14: ...on 1 Mark the laser points A1 and B1 with a pin Checking the accuracy of the lower plumb point Rotate the instrument by 180 so that it points in the opposite direction 2 to direction 1 Adjust the inst...

Страница 15: ...ce P1 Check afterwards the new reference point b2 with the old reference b1 on the front wall The deviation between the two points may be max 3mm Mark the new position of the right hand perpendicular...

Страница 16: ...visibility please clean the optics of your device regularly There fore blow off the dust from the glasses without touching the optics with your fingers If necessary use a damp soft cloth and a little...

Страница 17: ...led information about the International Limited Warranty can be found on the internet at www leica geo systems com internationalwarranty Calibration and repair service Leica Geosystems recommend to ch...

Страница 18: ...above is responsible for supplying the product including the User Manualin a com pletely safe condition The company above is not responsible for third party accessories Responsibilities of the person...

Страница 19: ...modified Carry out periodic test measurements Particularly after the instru ment has been subject to abnormaluse and before during and after important meas urements CAUTION Never attempt to repair th...

Страница 20: ...rting and shipping your measuring device Transport of Li Ion battery WARNING During transport shipping or disposalof batteries it is possible for inappropriate mechanicalinflu ences to constitute a fi...

Страница 21: ...reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the rece...

Страница 22: ...m or direct it towards other people unnecessarily Eye pro tection is normally afforded by aversion responses including the blink reflex WARNING Looking directly into the beam with opticalaids e g bino...

Страница 23: ...Safety instructions Labelling Subject to change drawings descriptions and technicaldata without prior notice Leica Lino P5 22...

Отзывы: