6: Context sensitive help
Select
•
Select
run
to enter a number of repetitions for this logging
session.
•
Select
repeat infinitely
to configure a logging session with no
defined end.
•
Select
run once
to configure only one interval for a logging
session.
Start next session
This setting is only active if repeat infinitely or repeat is selected in the No.
of repeats.
Configure the time for the next session to start as the number of days,
hours and minutes after the last session ended.
Note: The gap between logging sessions only has an impact if it is
repeated at least once. The length of the gap must not be more than 14
days 23 : 59 h.
Create a wake up session
Activate to create a wake-up session with the same timing settings as this
logging session.
When the check box is activated and the logging session is stored, a wake-
up session with the same name is created. This wake-up session has the
same time and repeat settings as the logging session.
After the logging session is stored and the wake-up session is created,
both can be edited and deleted independently. The logging session will
continue to run without the wake-up session if the receiver is turned on.
The wake-up session will run without the logging session if the receiver
was turned on.
Press
to go back to the previous wizard step. Press
to continue to the next wizard step.
Press
to cancel and return to
GNSS management: Logging session
Related topics
GNSS management / Site name and coordinates
135
Содержание GR10
Страница 1: ...Leica GR10 Operational Manual Online Help ...
Страница 23: ......
Страница 67: ......
Страница 215: ......
Страница 232: ...9 How to Related topics Slot in devices Device Management New Edit modem phone device Status Network connections 231 ...
Страница 243: ......
Страница 261: ......
Страница 289: ......
Страница 293: ......
Страница 309: ......
Страница 311: ...Printed Documentation N Ntrip O P Q R RINEX S T U V W WGS84 X Y Z 310 ...