Emspira 3 User Manual 

Objective and Illumination 31

To ensure eye safety, read the user 
manual of the illumination, in partti-
cular the safety instructions.

Assembly

The spot and diffuse illuminator is 
installed on the focusing column 
using an adapter.

The LED5000 SLI and its longer 
goosenecks should be avoided for 
installation on a large incident light 
base (10 450 049) or a transmitted 
light base. Leica Microsystems 
recommends the LED3000 SLI for 
installation on a small or medium  
incident light base (10 446 340 / 
10 447 342).

 

Installation on routine focusing columns

1

1.  Screw the spot illuminator to the adapter 

10 450 570.

2

2.  Install the adapter to the rear side of the 

focusing column. In doing so, the height 
can be adapted to your requirements.

Illumination: LED5000 SLI, LED3000 SLI, LED3000 DI

Содержание Emspira 3

Страница 1: ...Emspira 3 User Manual...

Страница 2: ...umination LED3000 RL 28 Illumination LED3000 NVI 30 Illumination LED5000 SLI LED3000 SLI LED3000 DI 31 Installation Stand Alone Mode Cables and Terminals 34 Stand Alone Mode Installing Optional Extern...

Страница 3: ...hnical Data 59 Optical Data Field of View 64 Optical Data Magnification and Depth of Field 66 Dimensional Drawings 68 Emspira 3 68 Emspira 3 With Incident Light Base 69 Emspira 3 With Incident Light B...

Страница 4: ...Emspira 3 User Manual General Notes 4 General Notes...

Страница 5: ...echniques for cleaning O Never use chemicals to clean colored surfaces or accessories with rubberized parts This could damage the surfaces and specimens could be contaminated by abra ded particles Ser...

Страница 6: ...booklet contains additi onal safety information regarding the service work requirements and the handling of Emspira 3 accessories and electrical accesso ries as well as general safety instructions You...

Страница 7: ...of hazardous electrical voltage This symbol indicates especially important information Failure to comply can cause the following O Personal injury O Emspira 3 malfunctions and damage Microscope malfu...

Страница 8: ...thorized alterations to Emspira 3 or noncompliant use shall void all rights to any warranty claims Place of use O Refer to Safety Concept booklet O Electrical components must be placed at least 10 cm...

Страница 9: ...osal O Refer to Safety Concept booklet Legal regulations O Refer to Safety Concept booklet EC Declaration of Conformity O Refer to Safety Concept booklet EMC precautions Prior to the installation of E...

Страница 10: ...e safety and EMC Our microscope has been designed produced and tested in compliance with O EN 61010 1 Safety requirements for elec trical equipment for measurement control and laboratory use Part 1 Ge...

Страница 11: ...an encryp tion which follows the Advanced Encryption Standard AES with a block and key size of 128 bits During any firmware update this password file will be deleted and the User will need to reenter...

Страница 12: ...Emspira 3 User Manual Introduction 12 Introduction...

Страница 13: ...0 2 160 4K UHD To be used on 4K monitors O 1 920 1 080 Full HD This resolution provides the characteristic imaging perfor mance for a Full HD capable monitor Standard delivery 1 2 The Emspira 3 system...

Страница 14: ...n on additional accessories such as objectives and adapters illumination or the dust cover for Emspira 3 please contact your Leica Microsystems authorized dealer You can find detailed descriptions of...

Страница 15: ...SB Type A 3 ON OFF switch 4 PC power supply connection USB Type C 5 Connection for handswitch footswitch 2 5 mm phone jack 6 Monitor port stand alone mode 7 USB SPEED port for stand alone operation in...

Страница 16: ...6 System Overview 1 2 4 3 5 6 This overview shows Emspira 3 in an example application with additional components 1 Emspira 3 2 Microscope carrier 3 Illumination 4 Focusing column 5 Baseplate 6 HD moni...

Страница 17: ...Emspira 3 User Manual Assembly 17 Assembly...

Страница 18: ...er shows an example of assembly of Emspira 3 on an incident light base Images and descriptions may vary when using another incident light base Assembling the column 2 2 1 Take the three provided screw...

Страница 19: ...with a short working distance 2 2 Alternatively install the microscope carrier upside down recommended variant for objectives with a large working distance Mounting Emspira 3 2 1 3 2 1 Unscrew the cl...

Страница 20: ...ry when using another transmitted light base Installing the column adapter 2 2 1 Take the three provided screws out of the packaging 2 Install the column adapter on the column using the three screws A...

Страница 21: ...ided screw recommended variant for objectives with a small working distance 2 2 Alternatively install the microscope carrier upside down recommended variant for objectives with a large working distanc...

Страница 22: ...this part of the setup General notes This chapter shows an example of assembly of Emspira 3 on a swing arm stand Images and descriptions may vary when using another swing arm stand Assembling the colu...

Страница 23: ...n the safety ring You can now rotate the horizontal arm in any direction desired The swing arm stand is designed so that Emspira 3 can be moved as desired However it may also be logical in some instan...

Страница 24: ...washer and safety screw Mounting Emspira 3 1 3 2 2 1 Unscrew the clamping screw 2 Place Emspira 3 in the microscope carrier so that the notch in the microscope housing and the lower clamping screw ov...

Страница 25: ...Emspira 3 User Manual Objective and Illumination 25 Objective and Illumination...

Страница 26: ...sassembly so that it does not fall onto the stage plate Remove all specimens from the stage plate first The objective is not part of the standard delivery of Emspira 3 2 2 Screw the compatible adapter...

Страница 27: ...ctive firmly during assembly and disassembly so that it does not fall onto the stage plate Remove all specimens from the stage plate first The objective is not part of the standard delivery of Emspira...

Страница 28: ...nect the external power supply unit 10 450 266 to the LED3000 RL 2 Attach the LED3000 RL to the objective from below 3 Tighten the locking screw The supported working distance is between 60 mm and 150...

Страница 29: ...minator We recommend assembling the accessories on the LED3000 RL on a table in reverse and then mounting them on the objective together 1 1 Attach the optional polarization set polari zer and analyze...

Страница 30: ...nect the external power supply unit 10450266 to the LED3000 NVI 2 Attach the LED3000 NVI to the objective from below 3 Tighten the locking screw The supported working distance is between 60 mm and 150...

Страница 31: ...should be avoided for installation on a large incident light base 10450049 or a transmitted light base Leica Microsystems recommends the LED3000 SLI for installation on a small or medium incident ligh...

Страница 32: ...power supply unit 10450266 to the LED5000 SLI LED3000 SLI or LED3000 DI The right and left side of the spot illumina tor both have a socket Second CTL2 socket An additional LED illuminator from Leica...

Страница 33: ...Emspira 3 User Manual Installation 33 Installation...

Страница 34: ...kit Using another adapter with incorrect voltage can substantially damage Emspira 3 The color of the LED indicates that the power supply is not sufficient it s red when the supply doesn t provide enou...

Страница 35: ...ut formatting and handling the USB thumb drive provided in order to prevent malfunctions during image acquisition File system and formatting The exFAT or FAT32 file system is required for the thumb dr...

Страница 36: ...ns Installation of the 10 monitor arm to the standard column is analogous to installation of the LED3000 SLI see Illumination LED5000 SLI LED3000 SLI LED3000 DI page 31 Proceed as follows to connect t...

Страница 37: ...lation Guide 1 After downloading the software follow the instructions for installing the software The computer must have sufficient free hard drive space ON OFF SS HDMI SPEED 2 Connect Emspira 3 to a...

Страница 38: ...Emspira 3 User Manual Installation 38 For information on adapting network and WLAN settings refer to the On Screen Display User Manual Network WLAN Settings...

Страница 39: ...Emspira 3 User Manual Startup Procedure 39 Startup Procedure...

Страница 40: ...ower supply detected O Only the preferred USB 2 0 port is powered O Further power reduction might be activated Stand alone mode Blue blinking O Emspira 3 is in fall back mode e g after a failed firmwa...

Страница 41: ...K monitor and a power supply 1 Set the ON OFF switch to ON to switch on Emspira 3 During the boot sequence the status LED is blinking green and switches to a conti nuous white the moment it is ready t...

Страница 42: ...d the live image is displayed on the computer Emspira 3 is ready to use 2 Start Leica Application Software X LAS X 3 Follow the instructions in the software for adjusting and acquiring an image For ad...

Страница 43: ...essing the buttons hold the keypad between your thumb and index finger Avoid tapping the keypad with just one finger if possible Use 1 1 Switch on the illuminator by briefly pres sing the ON OFF butto...

Страница 44: ...ght handed Adjusting the resistance Is the focusing drive too loose or too tight Does the equipment tend to slide downwards The resistance can be adjusted individually depen ding on the equipment weig...

Страница 45: ...optionally be operated either with or without click stops enabled Continuous zoom is possible when the click stops are disabled On the other hand when the click stops are enabled photographs measure...

Страница 46: ...Emspira 3 User Manual Operation Stand Alone Mode 46 Operation Stand Alone Mode...

Страница 47: ...mation on setting up and switching on Emspira 3 in stand alone mode refer to chapters O Stand Alone Mode Cables and Terminals page 34 O Switching on Emspira 3 page 41 subchapter Stand alone mode page...

Страница 48: ...Emspira 3 User Manual Operation PC Mode 48 Operation PC Mode...

Страница 49: ...tor General notes When connected to a PC the microscope image is always shown in the preview window of Leica Application Software X In addition a HD 4K monitor can be connected via the HDMI interface...

Страница 50: ...Emspira 3 User Manual Troubleshooting 50 Troubleshooting...

Страница 51: ...tomatically to the necessary resolu tion However if no image appears and the screen reports an error message like out of range or something similar you can reset the resolution to 1 080 p How to reset...

Страница 52: ...Emspira 3 User Manual Care and Maintenance 52 Care and Maintenance...

Страница 53: ...rt flush the surface using a syringe or by brushing it off with a camel hair brush before attempting to wipe it clean O Optical surfaces should be cleaned using a lint free cloth lens cloth or cotton...

Страница 54: ...ial alcohol When doing so follow the corresponding safety regulations O Remove dust with a bellows and a soft paintbrush O Clean the objectives with special optics cleaning cloths and pure alcohol Ser...

Страница 55: ...26529 HDMI cable 2 m 2 19002015 C Mount Cap 3 10 726 837 USB C USB A cable 4 10726490 Power supply with USB C connector 5 10726491 Wireless USB mouse 6 10747551 USB stick 64 GB Optional Sales Item Ite...

Страница 56: ...Emspira 3 User Manual Disposal 56 Disposal...

Страница 57: ...Service or Leica Sales on how to dispose of it Like all electronic devices Emspira 3 its compo nents and accessories may not be disposed of as general household waste Please observe the national laws...

Страница 58: ...Emspira 3 User Manual Specifications 58 Specifications...

Страница 59: ...Apo 1 0x objective adap ter 10447176 and 10450651 and a stage micrometer 10310345 across the entire FOV using the On Screen Display and a 28 4k monitor Accu racy data were determined either using fact...

Страница 60: ...measurement task 10450650 187 mm Achromatic 0 63 148 mm PlanApo 0 8x Adapter 10450652 Adapter for measurement task 10450651 112 mm PlanApo 1 0x Adapter 10450652 Adapter for measurement task 10450651...

Страница 61: ...2 1011 mm2 Discharge time 2 seconds from 1 000 V to 100 V Click stop feature Eight switchable positions for repetitive tasks Standard objective Z Series planapochromat 1 0x Additional objectives Achr...

Страница 62: ...on 15 W Supported software LAS X File formats JPG TIF BMP Color filter IR cut coating 650 nm not replace able Housing Characteristics Value Material PC ABS Antimicrobial surface AgTreatTM according to...

Страница 63: ...m computer PC mode LAS X mode or by external power supply stand alone mode Min computer configuration Please consult the software used Tested standards EN 55011 EN 61326 1 EN 61010 1 Power supply opti...

Страница 64: ...19 3 10 9 15 1 8 5 1 0 57 1 32 1 36 2 20 3 28 7 16 1 22 5 12 7 18 1 10 2 14 5 8 2 11 3 6 4 1 25 45 7 25 7 28 9 16 3 23 0 12 9 18 0 10 1 14 5 8 1 11 6 6 5 9 1 5 1 1 6 35 7 20 1 22 6 12 7 17 9 10 1 14 1...

Страница 65: ...Objective PlanApo 2 0x PlanApo 5 0x Working distance 39 mm 19 mm Field of view zoom setting FOVx FOVy FOVx FOVy 0 75 12 0 6 8 4 8 2 7 1 0 9 0 5 1 3 6 2 0 1 25 7 2 4 1 2 9 1 6 1 6 5 7 3 2 2 3 1 3 2 0 4...

Страница 66: ...14 61 1 0 09 4 0 15 1 1 4 24 1 0 6 30 1 0 36 39 1 0 22 48 1 0 14 60 1 0 09 77 1 0 06 5 0 19 1 0 9 30 1 0 4 38 1 0 23 48 1 0 14 60 1 0 09 75 1 0 06 961 1 0 04 6 0 23 1 0 6 36 1 0 3 45 1 0 16 58 1 0 10...

Страница 67: ...2 96 1 0 036 2 0 48 1 0 14 120 1 0 023 2 5 60 1 0 09 150 1 0 015 3 2 77 1 0 06 192 1 0 006 4 0 96 1 0 036 240 1 0 009 5 0 120 1 0 0223 300 1 0 004 6 0 144 1 0 016 360 1 0 003 28 0 75 52 1 1 0 128 1 0...

Страница 68: ...Emspira 3 User Manual Specifications 68 Dimensional Drawings Emspira 3 156 132 132 54 251 111 M60x1 29 3 29 3...

Страница 69: ...Emspira 3 User Manual Specifications 69 Emspira 3 With Incident Light Base 278 301 278 119 116 301 244 324 24 max 457 66 255 156 181 468...

Страница 70: ...Emspira 3 User Manual Specifications 70 Emspira 3 With Incident Light Base 420 325 126 154 24 max 658 534 510 262 325 420 156 181...

Страница 71: ...Emspira 3 User Manual Specifications 71 Emspira 3 With Transmitted Light Base 154 154 45 69 346 69 346 412 156 181 max 523 378 223 3 115 384 284...

Страница 72: ...Emspira 3 User Manual Specifications 72 Emspira 3 With Swing Arm Stand max 668 330 173 230 598 max 786 470 220 156...

Страница 73: ...to modifications LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH CONNECT WITH US www leica microsystems com Leica Microsystems Schweiz AG Max Schmidheiny Strasse 201 9...

Отзывы: