background image

20

Appendix

Leica DISTO™ D3a BT 776750 gb

D

GB

F

I

E

P

NL

DK

S

N

FIN

J

CN

ROK

PL

H

RUS

CZ

The direction keys

Eight direction keys (identified by a small arrow near 
the key) on the operator's keypad are used to 
manoeuvre the cursor. The direction keys become 
active when you switch to the second level (by 
pressing the 

 key). The distance measuring key is 

active in both levels. The functionality of the direction 
keys depends on the software used. 

Transmitting the measurement

If your software supports the direction keys use them 
to select the appropriate position for the cursor. 

Press the 

 button briefly to transfer the value 

from the summary row to the pocket PC / PC. 

Press the 

 botton long to transfer all values from 

the display.

For further details please consult your manual for the 
software used.

During data transmission

If the data is not confirmed as being successfully 
received by the Pocket PC/ PC then no new measure-
ment can be processed. The Info code "240" appears 
in the display if no data transmission has taken place 
after 2 seconds. Press the 

 - key and repeat 

the measurement and then transmit it.

)

The free software supplied is designed to 

provide the user with basic functionality. Leica 
Geosystems provides no warranty for this free soft-
ware and offers no support for it. Leica Geosystems 
accepts no liability whatsoever arising from the use 
of the free software and is not obliged to provide 
corrections nor to develop updates or upgrades.
You can find numerous commercial vendors of soft-
ware for a wide range of applications on our 
homepage.

Appendix

Message codes

All message codes are displayed with either 

 or 

"Error". The following errors can be corrected:

Cause

Remedy

156

Transverse tilt 
greater than 10°

Hold the instrument 
without any transverse 
tilt

160

Main tilt direction, 
angle too high 
(> 45°)

Measure angle up to 
max. ± 45°

204

Calculation error

Repeat procedure

240

Data transfer error

Repeat procedure

Содержание DISTO D3a BT

Страница 1: ...Safety Instructions Symbols used The symbols used in the Safety Instructions have the following meanings WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided...

Страница 2: ...perma nently habitable by humans do not use the product in explosion hazardous areas or in aggressive envi ronments Areas of responsibility Responsibilities of the manufacturer of the orig inal equip...

Страница 3: ...asuring sensor not as a control device Your system must be configured and operated in such a way that in case of an erroneous measurement malfunction of the device or power failure due to installed sa...

Страница 4: ...vision reception which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate th...

Страница 5: ...rdance with IEC60825 1 2007 Radiation safety of laser products Laser Class 2 products Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afford...

Страница 6: ...orrect polarity 3 Close the battery compartment again Replace the batteries when the symbol flashes perma nently in the display Only use alkaline or rechargeable batteries Remove the batteries before...

Страница 7: ...ng bracket until it locks in place then push the positioning bracket lightly to the right to fold it out fully A built in sensor automatically detects the orienta tion of the positioning bracket and a...

Страница 8: ...ll up constant value 11 Historical memory call up values 12 Spirit level numeric 13 Battery status 14 Area volume 15 Tilt 16 Horizontal distance measurement using tilt 17 Triangle area 18 Timer 19 Men...

Страница 9: ...The instrument can be specifically configured to your personal requirements General description button pressed long You are in the the units set and the first menu item Unit are displayed button press...

Страница 10: ...rements with a tripod To do this select ON in this menu item You can switch the reference on the tripod on or off The setting can be seen on the display Beep You can switch the beep on or off Level in...

Страница 11: ...hows the battery symbol until the next button is pressed Pressing this button for longer switches the instrument off The instrument switches off automatically after six minutes of inactivity CLEAR but...

Страница 12: ...nd up to max a transverse tilt of 10 Press the button for longer to display additional information on the measurement for example the tilt angle the distance measured and the indi rect height Press bu...

Страница 13: ...evice switches off automatically after 15 minutes Functions Addition subtraction Distance measuring The next measurement is added to the previous one The next measurement is subtracted from the previo...

Страница 14: ...ent e g width Press this button to take the third length measure ment e g height The volume then appears in the summary line Press the button for longer to display additional room information such as...

Страница 15: ...first two measurements and the perimeter of the triangle Stake out function Two different distances a and b can be entered into the instrument and can then be used to mark off defined measured length...

Страница 16: ...er a or b As soon as the stake out point is reached the beep changes The function can be stopped at any time by pressing the button Indirect measurement The instrument can calculate distances using Py...

Страница 17: ...possible Press and hold down this button to trigger continuous measurement sweep the laser back and forth and up and down over the ideal target point Press to stop continuous measurement 2 The result...

Страница 18: ...s 2 Triggers the measurement After the second measurement the value is adopted The display flashes 3 Press and hold down this button to trigger continuous measurement Sweep the laser up and down over...

Страница 19: ...asurement e g 59 58 57 are displayed in a countdown The last 5 seconds are counted down with a beep After the last beep the measurement is taken and the value is displayed The timer can be used for al...

Страница 20: ...g successfully received by the Pocket PC PC then no new measure ment can be processed The Info code 240 appears in the display if no data transmission has taken place after 2 seconds Press the key and...

Страница 21: ...e Remedy Error Hardware error Switch on off the device several times If the symbol still appears then your instrument is defective Please call your dealer for assistance Cause Remedy Distance measurem...

Страница 22: ...ss liquids e g water or dust free glass Styrofoam or similar semi permeable surfaces Aiming at high gloss surfaces may deflect the laser beam and lead to measurement errors Against non reflective and...

Страница 23: ...ope or camera Warranty The Leica DISTO D3a BT comes with a three year warranty from Leica Geosystems AG More detailed information can be found at www disto com All illustrations descriptions and techn...

Страница 24: ...24 Appendix Leica DISTO D3a BT 776750 gb D GB F I E P NL DK S N FIN J CN ROK PL H RUS CZ...

Страница 25: ...Quality Systems ISO standard 9001 and Environmental Management Systems ISO standard 14001 Total Quality Management Our commitment to total customer satisfaction Ask your local Leica Geosystems agent f...

Отзывы: