Leica DISTO A2 Скачать руководство пользователя страница 7

4

Appendix

Leica DISTO™ A2 1.1.0 gb

d

GB

F

I

E

P

NL

DK

S

N

FIN

J

CN

ROK

PL

H

RUS

CZ

Appendix

Display Notices

All display notices are indicated by "InFo" or "Error". 
The following errors can be corrected.

Technical Specifications

* in favourable conditions (optimal target surface, room 
temperature) up to 12 m. In unfavourable conditions, such as 
intensive sunshine, very weakly reflecting target surface or 
large temperature fluctuations, measuring accuracy may 
deteriorate to approx. ± 0.25 mm/m for distances above 
12 m.

InFo

Cause

Correction

252

Temperature too 
high

Let device cool down.

253

Temperature too low Warm device up

255

Received signal too 
weak, time for a 
measurement too 
long.

Use a target plate

256

Received signal too 
strong

Use a target plate 
(gray side)

257

Faulty measurement, 
too much back-
ground light

Use a target plate 
(brown side)

Error

Cause

Correction

Hardware error

If this message 
remains displayed 
after switching the 
device off and on 
several times, please 
contact our dealer-
ship. 

Range (for extended 
distances, use a target 
plate)

0,05 m to 60 m

(0.2 ft to 197 ft)

Measuring accuracy (2 

σ

)

typically: ± 1.5 mm 

(0.06 inch)*

Smallest unit displayed

1 mm

Laser class

II

Laser type

635 nm, < 1 mW 

Automatic 
power off

after 180 s

Display illumination

9

Continuous measure-
ment

9

Addition / subtraction

9

Battery life, 
9 V compound battery

up to 5000 measurements

Dimensions and weight

124x54x35 mm, 155 g

Temperature range:
Storage

Operation

-25°C to +70°C

(-13°F to +158°F)

-0°C to+40°C

(+32°F to + 104°F)

Содержание DISTO A2

Страница 1: ...Leica DISTO A2 The original laser distance meter ...

Страница 2: ......

Страница 3: ......

Страница 4: ...y 7 MINUS key Display See drawing B 1 Laser ON 2 Reference front rear 3 Area volume 4 Battery symbol 5 Main targets 6 Units with exponents 2 3 7 Second row e g intermediate values Start up Inserting Replacing Batteries Remove the battery cover insert the battery correctly Close the battery compartment Replace the battery when this symbol constantly blinks in the display Only use alkaline batteries...

Страница 5: ...ontinuous Measurement This functions enables distances to be staked out See drawing D The last measured value is displayed in the summary row Functions Addition Subtraction Distance Measurement Repeat this procedure for as many times as required The result is always displayed in the summary row the previous value is displayed in the second row Device and laser are switched on Holding down this key...

Страница 6: ...king out distance or multiples of it are displayed in the auxiliary line the laser measuring starts In the main line the distance between the staking out point in the auxiliary line and the DISTO rear measuring reference is displayed If the DISTO is moved along the staking out line the displayed distance is reduced At a distance of 0 1 m to the next staking out point the DISTO starts to beep As so...

Страница 7: ...eak time for a measurement too long Use a target plate 256 Received signal too strong Use a target plate gray side 257 Faultymeasurement too much back ground light Use a target plate brown side Error Cause Correction Hardware error If this message remains displayed after switching the device off and on several times please contact our dealer ship Range for extended distances use a target plate 0 0...

Страница 8: ... polystyrene or similar semi translucent surfaces as well as from highly reflecting targets that deflect the laser Care Clean with a soft damp cloth Never immerse the unit in water Never use aggressive cleaning agents or solvents Warranty The Leica DISTO A2 comes with a three year warranty from Leica Geosystems AG More detailed information can be found at www disto com All right reserved for chang...

Страница 9: ......

Страница 10: ... Quality Systems ISO standard 9001 and Environmental Management Systems ISO standard 14001 Total Quality Management Our commitment to total customer satisfaction Ask your local Leica Geosystems agent for more information about our TQM program Printed in Switzerland Copyright Leica Geosystems AG Heerbrugg Switzerland 2007 Translation of original text 752828b Pat No WO 9427164 WO 9818019 WO 0244754 ...

Отзывы: