Specification of USB
po
r
t
Specification of
LAN/WAN po
r
t
Specification of
RS232 po
r
t
Top
Earth protection connector. Connected to the ground
of the power supply V GND. If used, connect a yellow-
green marked cable with at least 6 mm
2
copper area.
Avoid corrosion and protect the screws against loos-
ening.
Top
Power supply 12–48 V DC (Pin 1/Pin 2). Additional
power supply (redundancy) 12–48 V DC (Pin 3/Pin 4).
Top
Non-isolated serial RS232 interface (Pin 5 to Pin 7).
Can be used for serial device server or other serial
based communication applications.
Top
Galvanic isolated digital outputs (Pin 8 to Pin 11).
Default position of circuit breaker:
• DO1: Open
• DO2: Closed
Top
Galvanic isolated digital inputs (Pin 12 to Pin 15).
Top
• To reboot press at least 3 s.
• To reset to factory settings press at least 35 s.
The start of the factory reset is confirmed by
all LEDs lighting up for a second. The button
can be released then again.
Po
r
t
Panel
Desc
r
iption
Feat
ur
e
Specification
Speed
Low, Full and Hi-Speed
Current
Max. 500 mA
Feat
ur
e
Specification
Isolation
1500 Vrms
Speed
10/100 Mbps
Mode
Half- and Full-Duplex
Crossover
Automatic MDI/MDI-X
Feat
ur
e
Specification
Protocol
3-wire RS-232 (TXD, RXD, GND)
Baud rate
300, 1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200
Data bits
7 bit, 8 bit
Parity
none, odd, even
Stop bits
1, 2
Software flow control
None, XON/XOFF
Hardware flow control
None