Leica ComGate10
User Manual
Version 3.0
English
Mo
nit
or
in
g
So
l
u
ti
o
n
s
Страница 1: ...Leica ComGate10 User Manual Version 3 0 English Monitoring Solutions...
Страница 2: ...d States and other countries All other trademarks are the property of their respective owners Feedback Your feedback is important as we strive to improve the quality of our documentation We request yo...
Страница 3: ...n Leica Geosystems service centres Access detailed informa tion on the services performed and download your latest calibration certificates and service reports mySupport View the current service statu...
Страница 4: ...2 1 Hardware Concept 12 2 2 2 Software Concept 13 2 2 3 Power Concept 14 2 3 ComGate10 and available accessories 14 2 4 System Components 15 2 4 1 ComGate10 15 2 4 2 Cables 16 3 Operation 20 3 1 Prep...
Страница 5: ...G CAUTION and NOTICE are standardised signal words for iden tifying levels of hazards and risks related to personal injury and property damage For your safety it is important to read and fully underst...
Страница 6: ...l safety authorities and safety experts must be contacted before working in hazardous areas or close to electrical installations or similar situations by the person in charge of the product Environmen...
Страница 7: ...force in your country regarding grounding antennas and masts These installations must be carried out by an authorised specialist To prevent damages due to indirect lightning strikes voltage spikes cab...
Страница 8: ...o the regulations governing safety accident prevention and road traffic WARNING If the product is improperly disposed of the following can happen If polymer parts are burnt poisonous gases are produce...
Страница 9: ...Malfunction and Electric Shock Improper handling of the power plug or cord for example mechanical damage or heat may cause fire malfunction or cause you to receive an electric shock Precautions Handle...
Страница 10: ...e product is operated with connecting cables attached at only one of their two ends for example external supply cables interface cables the permitted level of elec tromagnetic radiation may be exceede...
Страница 11: ...ference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the u...
Страница 12: ...hentication method Challenge Handshake Authenti cation Protocol CHAP or Password Authentication Protocol PAP The knowledge about the PPP Point to Point Protocol DNS query Specification whether a DNS r...
Страница 13: ...the mobile Internet WLAN connection can be purchased as an official accessory 2 2 2 Software Concept Configuration The delivered ComGate10 is preconfigured Leica ComBox Manager The ComBox Manager soft...
Страница 14: ...never disassemble or modify the Leica M Com series products without any advices from Leica Geosystems NOTICE Unplugging connecting cables from the ComGate10 during a continuous system causes malfuncti...
Страница 15: ...us LEDs h Connector for first UMTS LTE antenna i Connector for second UMTS LTE antenna MIMO mode j Connector for first WLAN antenna k Connector for second WLAN antenna MIMO mode a Label b Galvanic iso...
Страница 16: ...d from Leica Geosystems Leica TPS1000 TPS1100 TPS1200 cable Interface cable GEV241 Leica TM30 TS30 cable Interface cable GEV240 a Status LED b Mobile LED c VPN LED d WLAN LED e USB LED 006179_001 a b...
Страница 17: ...ndard plug type A Cable features Interface ComGate10 GMX910 Transmission Data and power Type Shielded Length 5 m Wires 5 Lemo pins 8 Unterminated Cable features Interface ComGate10 GMX902 Transmission...
Страница 18: ...delivers no USB to serial converter ATEN UC 232A Leica Geosystems delivers no RS232 485 converter It is a product of ICP DAS Co http www icpdas com Cable features Interface ComGate10 RS232 485 conver...
Страница 19: ...dard cables to the ComGate10 The cables must be organised locally Only an appropriately trained and qualified specialist may install warning devices with a ComGate10 Refer to chapter 5 Technical Data...
Страница 20: ...omBox dyndns org Server address normally members dyndns org Server port normally 80 or 8245 Configuring ComGate10 by computer Step Description 1 Open the card box 2 Check that the items from the packi...
Страница 21: ...tems authorised service centres are entitled to open the product Otherwise the warranty expires immediately 3 Open the SIM card holder 4 Insert a SIM card from your mobile provider in the SIM card hol...
Страница 22: ...o the first connector VGND of the terminal block 2 Connect the red wire of the power supply to the second connector V After the activation of the ComGate10 you have to wait until the ComGate10 is init...
Страница 23: ...lation 3 Check if the PC laptop can obtain an IP address automatically a Click Windows Start Run b Type in ncpa cpl and press Enter c Click left mouse button on Local Area Connection d Select Properti...
Страница 24: ...ress Enter c Click left mouse button on Local Area Connection d Select Properties e Select Internet Protocol Version 4 TCP IPv4 f Click Properties g Select Obtain an IP address automatically 3 Start L...
Страница 25: ...network with Internet access WLAN interface The WLAN interface can act as an access point and therefore provide IP addresses to clients or act as client and connect to an existing WLAN By default the...
Страница 26: ...AN antenna should be fastened in a vertical position with the delivered screws and drill plug anchors Mounting installation for the antenna guide is delivered within the antenna box Cable installation...
Страница 27: ...nect the sensor cables to the terminal block Ensure the shields of all outgoing sensor cables inclusive GNSS antenna and Ethernet cables are also grounded Setup with MS60 TS60 MS50 TM50 TS50 USB conne...
Страница 28: ...S16 Series TS15 Series TPS1000 1100 1200 Geodetic Sensor GEV240 772 183 GEV241 772 184 GEV270 807 696 722 411 COMGT10LWEU 853 396 CT AT467 853 397 006187_002 COMGT10LWEU 853 396 GEV97 560 130 GEV197 7...
Страница 29: ...V108 632 390 30m GVP653 765 734 AR25 765 733 GEV160 733 280 AR10 773 758 GMX902 GG 758 600 GMX902 GNSS 773 974 GEV247 779 138 GEV270 807 696 722 411 CT AT467 853 397 ATEN UC 232A GEV207 748 489 GEV204...
Страница 30: ...GEV207 748 489 CAT6 cable GEV207 748 489 NIVEL220 567 199 GEV207 748 489 CAT6 cable NIVEL220 567 199 CAT6 cable GEV207 748 489 GEV207 748 489 NIVEL220 567 199 575 869 RS232 RS232 485 Converter 722 411...
Страница 31: ...appropriately trained and qualified specialist may install warning devices with a ComGate10 ATEN UC 232A RS232 RS232 485 Converter 722 411 GEV270 807 696 Power cable TP meteo sensor RS485 837 816 1413...
Страница 32: ...upply for instrument a For example GEV271 Max current 1 A Max switching voltage 60 V AC DO1 Normally Closed it is connected when the relay coil is off DO2 Normally Open it is connected when the relay...
Страница 33: ...The mobile connection is up red low quality connection yellow medium quality connection green best quality connection The mobile connection is being established The mobile connection is down VPN LED...
Страница 34: ...to protect against shock and vibration 4 2 Storage Product Respect the temperature limits when storing the equipment particularly in summer if the equipment is inside a vehicle Refer to 5 Technical Da...
Страница 35: ...Electrical data Mobile interface Environmental specifications The following precautions must be taken before installing a ComGate10 router Avoid direct solar radiation Protect the device from humidit...
Страница 36: ...on updates Front Ethernet port To connect the ComGate10 to another device for example WebCam or PC Can be used as LAN or WAN interface Front Ethernet port To connect the ComGate10 to the Internet Can...
Страница 37: ...ted digital outputs Pin 8 to Pin 11 Default position of circuit breaker DO1 Open DO2 Closed Top Galvanic isolated digital inputs Pin 12 to Pin 15 Top To reboot press at least 3 s To reset to factory s...
Страница 38: ...Minimum voltage for level 1 set 7 2 V DC Maximum voltage for level 0 not set 5 0 V DC Pin Name Description 1 Tx Transmit data 2 Tx Transmit data 3 Rx Receive data 4 5 6 Rx Receive data 7 8 1 2 3 4 5 6...
Страница 39: ...mp assign ment 1 Red Power in V 2 3 Blue Ground V GND 4 Green Data in TxD 5 Black Data out RxD 1 2 3 4 5 006216_001 Interface cable GEV240 Connector pin assignment Wire coding Sensor signal Terminalbl...
Страница 40: ...lack Data out RxD 6 7 Red Power in V 8 006158_001 1 2 3 4 5 6 7 8 Interface cable GEV247 Connector pin assignment Wire colour Sensor signal Terminalblock clamp assign ment 1 Brown Power in V 2 White G...
Страница 41: ...ower in V 5 Black Ground V GND DB9 cable RS232 RS232 485 converter Power supply cable Connector pin assignment Signal Terminal block clamp assignment 1 Power in V 2 Ground V GND 1 2 3 4 5 006216_001 0...
Страница 42: ...t 2 rec To switch the digital output Possible channel numbers 1 2 Possible actions on To close the circuit breaker of the digital output off To open the circuit breaker of the digital output rec Stand...
Страница 43: ...e put into service without restric tions in any EEA member state The conformity for countries with other national regulations not covered by the FCC part 15 22 and 24 or European directive 1999 5 EC h...
Страница 44: ...stributor You must not install or use the software unless you have read and accepted the terms and conditions of the Leica Geosystems Software Licence Agreement Installation or use of the software or...
Страница 45: ......
Страница 46: ...ystems AG Heinrich Wild Strasse CH 9435 Heerbrugg Switzerland Phone 41 71 727 31 31 www leica geosystems com 816902 3 0 0en Original text Published in Switzerland 2017 Leica Geosystems AG Heerbrugg Sw...