NA2/NAK2-2.0.0en
34
Technical Data
Accuracy:
• Standard deviation for 1km
double levelling, depending on
staffs and procedure
up to 0.7 mm
• With GPM3 parallel-plate
micrometer (optional)
0.3 mm
Telescope:
• Vertical image
• Magnification,
standard eyepiece
32 x
FOK 73 eyepiece
40 x
• Clear objective diameter
45 mm
• Field of view at 100 m
2.2 m
• Shortest target distance
from instrument axis
1.6 m
Distance measurement:
• Multiplication factor
100
• Additive constant
0
Compensator:
• Working range
± 30‘
• Setting accuracy (stand. dev.)
0.3“
Technical Data
Circular level:
• Sensitivity
8‘ / 2 mm
Glass circle of NAK2:
• Graduation
360º or 400 gon
• Graduation diameter
70 mm
• Graduation interval
1º or 1 gon
• Optical scale interval
10‘ or 10
c
• Reading by estimation to
1‘ or 1
c
Temperature range:
• Storage
-40ºC to 70ºC
(-40ºF to 158ºF)
• Operating
-20ºC to 50ºC
(-4ºF to 122ºF)
GPM3 parallel-plate micrometer:
(optional accessory)
• Range
10 mm
• Interval
0.1 mm
• Estimation
0.01 mm