7
Technical Data
7.1
Angle Measurement
Available angular accuracies
Standard deviation
Hz, V
ISO 17123-3
["]
[mgon]
9
2.8
Absolute, continuous, diametric.
7.2
Distance Measurement with Reflectors
Shortest measuring distance:
1.5 m
Maximum measuring distance:
80 m
Measurements can be made to reflector tapes over the entire range without
external ancillary optics.
Accuracy refers to measurements to standard prisms.
Distance
measuring
mode
Standard
deviation
ISO 17123-4,
standard prism
Standard
deviation
ISO 17123-4,
tape
Measurement
time, typical [s]
Single Auto
1 mm
3 mm
2.4
Continuous
with lock
3 mm
3 mm
< 0.15
Beam interruptions, severe heat shimmer and moving objects within the beam
path can result in deviations of the specified accuracy.
Type
Description
Principle
Phase measurement
Type
Coaxial, visible red laser
Carrier wave
658 nm
Measuring system
System Analyzer Basis 100–150 MHz
7.3
Distance Measurement without Reflectors
R80
Kodak Gray Card
Range
[m]
[ft]
White side, 90 % reflective
80
260
Grey side, 18 % reflective
80
260
Range of Measurement:
1.5 m to 80 m
Accuracy
Characteristics
Range
☞
Accuracy
Characteristics
Range
Technical Data
53