Leica DISTO
TM
S910 808167a
49
EN
Message Codes
If the message
Error
does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message
InFo
appears with a number,
press the Clear button and observe the
following instructions:
Care
•
Clean the device with a damp, soft cloth.
•
Never immerse the device in water.
•
Never use aggressive cleaning agents or
solvents.
Functions
Distance measuring
yes
Min/Max measuring
yes
Permanent measuring
yes
Stake-out
yes
Addition/Subtraction
yes
Area
yes
Triangle area
yes
Volume
yes
Trapezium
yes
Painter function (area with partial
measurem.)
yes
Pythagoras
2-point, 3-point
Smart Horizontal Mode /
Indirect height
yes
Height-profile measurement
yes
Level
yes
Sloped objects
yes
Height tracking
yes
Memory
yes
Beep
yes
Illuminated colour display
yes
Pointfinder (Viewscreen)
4x zoom, OV
Bluetooth
®
Smart
yes
Personalized Favorites
yes
Timer
yes
Calculator
yes
Photo/Screenshot
yes
Compass
yes
Gallery with USB download
yes
Diameter
yes
Width
yes
Area from Photo
yes
Smart Base
yes
Pointdata transmission
yes
Point to point function /distance
yes
Smart Angle
yes
Smart Area
yes
DXF Data capture
yes
No.
Cause
Correction
156
Transverse tilt
greater than 10°
Hold the instrument without
any transverse tilt.
162
Calibration mistake Make sure, the device is
placed on a absolutely hori-
zontal and flat surface.
Repeat the calibration
procedure. If the mistake still
occurs, contact your dealer.
204
Calculation error
Perform measurement again.
240
Data transfer error Repeat procedure.
252
Temperature too
high
Let device cool down.
253
Temperature too
low
Warm device up.
255
Received signal too
weak, measuring
time too long
Change target surface (e.g.
white paper).
256
Received signal too
high
Change target surface (e.g.
white paper).
No.
Cause
Correction
258
Measurement outside
of measuring range
Correct range.
260
Laser beam inter-
rupted
Repeat measurement.
300
Smart Base not folded
out
Fold out Smart Base.
301
Device was moved,
levelling not valid any
more
Perform levelling again.
Measuring with invalid
levelling is possible, but it
affects the accuracy.
302
«Point data transmis-
sion» is selected, but
WLAN is off
Switch on WLAN.
340
WLAN: Data transfer
error
Repeat procedure.
341
Authentication Error
Use correct password.
www.
.com
1.800.561.8187