![LEHNER POLARO Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/lehner/polaro/polaro_operating-manual_1872370023.webp)
POLARO
®
error message list
7 POLARO
®
error message list
Error
Cause
Solution
E1 - Supply voltage
< 9 V.
Please ensure adequate power supply.
E2 = Agitator
blocked
Occurs if the agitator has not freed
itself after 10 reversals of starting
direction.
Switch off the control panel Empty hopper and
check for foreign bodies.
E3 = Disc motor
blocked
Occurs if the spreader disc does not
start of is blocked.
1. Check the cabling to the motor.
2. Check that spreader disc is free to rotate.
3. If necessary, apply 12 Volt supply direct to
spreader disc motor.
E4 = Slider error
Contact the manufacturer
E5 = Agitator fault
Occurs if the agitator is not plugged in
or if the cable if broken.
Check cabling to motor and, if necessary, apply
12 V supply direct to motor.
POLARO
®
1.1
23 / 34
Содержание POLARO
Страница 21: ...Appendix 6 4 Parts list POLARO 5 7 4 1 2 3 6 POLARO 1 1 21 34 ...
Страница 28: ...Attaching POLARO to the Husqvarna Rider P 500 series 28 34 1 1 POLARO ...
Страница 29: ...Attaching POLARO to the Husqvarna Rider P 500 series POLARO 1 1 29 34 ...
Страница 31: ...Attaching POLARO to the Husqvarna Rider P 500 series 23 24 25 26 27 28 70mm 45mm 44mm POLARO 1 1 31 34 ...
Страница 32: ...Attaching POLARO to the Husqvarna Rider P 500 series 29 30 45 31 32 33 34 32 34 1 1 POLARO ...
Страница 33: ...Attaching POLARO to the Husqvarna Rider P 500 series 35 36 37 38 39 POLARO 1 1 33 34 ...
Страница 34: ...Attaching POLARO to the Husqvarna Rider P 500 series 34 34 1 1 POLARO ...