Delta | User handbook
Version 07/2022
page 17
7.2
Status messages on the display
Contact UP
The drive-up is prevented by the pressed contact bar or the pressed
upper access ramp.
Contact DOWN
Departure is prevented by the pressed contact bar or the pressed lower
access ramp.
Safety bottom
The descent is prevented by the pressed contact bottom, i.e., the ascent
must still be possible.
S11o
Occurs when driving with the landing controls and the platform is not
completely closed or when the switch S11o is not properly set (switch
S11o not actuated although it should be).
S11p
Occurs when driving with the platform handset and the platform is not
fully opened or when the switch S11p has not been set properly (switch
S11p not actuated although it should be).
S11m
Occurs when the platform motor does not operate switch S11m. The
switch S11m may not be set correctly.
S11s
Occurs when a barrier arm is not in the correct position. This could be
when a barrier arm has been emergency unlocked. (Switch S11s not
actuated although it should be).
S11u
Displayed when the barrier arms are unfolded and they are already
fully open.
S33
Occurs when the side access ramp for the 2nd actuator is not closed
correctly.
Overcurrent
Occurs when the actuator motor draws too much current during
folding. The overcurrent threshold of the platform motors can be
adjusted via potentiometers R50 and R63 on the platform board.
Upper / lower HS
The platform can no longer be moved because it is already in a
terminal stop.
Not in station
Displayed when you want to unfold the platform even though the lift is
not in any landing.