background image

Ins

tallation Ins

tructions

Please read all instructions before installing

DESCRIPTION AND OPERATION

The RS-350-N PIR Dual Relay Universal Application Wall Switch Vacancy Sensor 
is designed to replace two single pole standard residential switches or one 
combination switch (“double switch”). It is ideal for living and dining rooms, family 
rooms, bedrooms, bathrooms and any other indoor area in a residential space 
where occupancy sensor-based manual ON/OFF control of two different loads 
(i.e., a lamp and a fan) from a single location is desirable.

Like a standard combination switch, you press either or both of the two ON/OFF 
buttons to turn lights and/or fans (controlled loads) ON and OFF. Unlike a 
standard combination switch, the RS-350-N automatically turns OFF the 
controlled loads after the coverage area has been vacant for a period of time 
(Time Delay). If motion is detected within 30 seconds after they automatically turn 
OFF, the RS-350-N automatically turns the loads back ON.

While the sensor is factory preset as a Vacancy Sensor with manual-ON 
operation, it can be adjusted to work as an Occupancy Sensor that turns the 
controlled loads ON automatically upon detection of occupancy in the area.

Lighted Switch

To help you locate the RS-350-N in a dark room, an amber LED illuminates 
each of the ON/OFF buttons while the controlled loads are OFF. When one of the 
controlled loads is ON, the corresponding LED is OFF.

Nightlight

While the controlled load connected to relay #1 is OFF, the nightlight built into the 
RS-350-N is ON. When this load is ON, the nightlight is OFF.

Operating Modes

There are two operating modes that can be selected independently for each relay 
during set up:

MODE 1 Vacancy sensor

 (Manual-ON/OFF, Auto-OFF): The user must press the 

ON/OFF button to turn the load ON. The RS-350-N keeps the load ON until no 
motion is detected for the selected time delay period (adjustable from 15 seconds 
to 30 minutes). There is a 30 second reset delay. If motion is detected during this 
time, the sensor turns the load back on automatically. After the reset delay time 
has elapsed, the ON/OFF button must be pressed to turn ON the load.

MODE 2 Occupancy sensor

 (Auto-ON/OFF with manual control and reset to auto 

after 5 minutes of vacancy): The load turns ON and OFF automatically based on 
occupancy detection. The RS-350-N keeps the load ON until no motion is detected 
for the selected time delay period. If the load is turned OFF manually, automatic-
ON is re-enabled when no motion is detected for 5 minutes. This prevents the 
load from being turned ON after it was deliberately turned OFF.

RS-350-N

PIR Dual Relay Universal Application

Wall Switch Vacancy Sensor

with Manual ON/OFF

   

Lens

ON/OFF button for Relay 1
     ON/OFF button for Relay 2

SPECIFICATIONS

Voltage ............................................................... 120VAC, 60Hz
Load rating for each relay
 

Incandescent or fl uorescent ............................ 0-600 Watts

 

Fan motor ..................................................................  1/6 hp

Time Delay Adjustment .................... 15 seconds to 30 minutes
Light Level Adjustment ....................................... 10 fc to 150 fc
Environment ..................................Residential Indoor use only
 

Operating Temperature ............... 32° to 131°F (0° to 55°C)

 

Humidity ...................................... 95% RH, non-condensing

Tools Needed
 Insulated 

Screwdriver

 Wire 

Strippers

Santa Clara, CA 95050

Call 888.817.0571 for Technical Support

Nightlight