Doc No. FM0471 issue G Page 2  

Testing & Registering the Gas & CO Detector 

 

The

 

TRANSMIT GAS

 

and

 

TRANSMIT CO

 

pushbuttons on the lid 

are used when registering the combined Gas & CO detector  
onto the warden call system, at-home alarm or Nursecall system.

 

 

 

 

 

 

 

 

See the following pages for how to put each of these products into registration mode.  

 

The range of all radio devices can be affected by the working environment, 
always take care during installation and perform several test calls.

 

 

Important Note on Sensor Testing 

 

The gas and CO detector should be functionally tested every 6-12 months (depending on location).  
The gas sensor can only be tested with calibrated test gas, never test using neat gas as this will poison the sensor. 
The CO sensor can only be tested with calibrated test CO, this will take less than 1 minute to trigger.  
For test gas supplies please contact Duomo. 

 

In Case of Gas Alarm 

 

If gas is detected the 

RED

 

ALARM GAS

 light will illuminate, and the audible alarm will sound. 

 

Put out all naked flames.  

Don’t smoke. Don’t use naked flames.

 

Don’t tu

rn electrical switches on or off. 

Turn the gas off at the supply. 
Open windows and doors to ventilate the area. 

 

The alarm will silence when the gas is cleared. If the alarm continues to sound and the leak cannot be found, vacate the premises 
and inform the Gas Emergency Service immediately. 

 

In Case of Carbon Monoxide Alarm 

 

If carbon monoxide is detected the 

RED

 

ALARM CO

 light will illuminate, and the audible alarm will sound. 

 
 
Open windows and doors to ventilate the area.

 

 

 

If the alarm stops it is safe for a qualified person to find the cause of the alarm.  
If the alarm continues turn the appliance off and do not use until it has been checked by a qualified person. 
Get medical help for anyone suffering headaches or nausea, advise that carbon monoxide poisoning is suspected. 

 

In Case of Fault 

If the 

YELLOW

 

FAULT

 light illuminates the self test feature has detected a fault with the sensor.  

The unit is probably defective and must be replaced. 

 

 

After 6 years the 

YELLOW

 light will blink continuously, and the unit will emit a beep every hour.  

The sensor has exceeded its useful life and must be replaced. 

 

False Alarms 

 

It is possible aerosol sprays, alcohol used in cooking, cigarette, cigar or  
pipe smoke, gas from a cigarette lighter, strong household cleaning 
agents, polishes or solvents may cause false alarms.

 

 

Cleaning and Care 

 

It is recommended to clean the gas & CO detector periodically using the nozzle attachment on a vacuum  
cleaner to remove dust, insects and cobwebs from the cover slots. 
The detector can be wiped clean with a damp cloth, never use detergents or polish etc. 
Avoid spraying any aerosols near the detector. 

 

Decorating 

 

Never paint the gas & CO detector itself.  
Unplug the mains supply and cover the detector when decorating to 
avoid contamination from water or dust. 

 

Battery Life 

 

The transmitter battery is checked once a day, if the voltage falls and stays below a preset level for 7 consecutive days a low 
battery alert is automatically transmitted. Once a low battery call is received the gas & CO detector should be replaced within 7 
days. The gas & CO detector must be returned to Tynetec/Aidcall for battery replacement.  
Detailed information on battery management for all Tynetec/Aidcall products is available - request Doc No. FM0630.  
 
 

 

TRANSMIT 

CO 

TRANSMIT 

GAS 

Содержание tynetec Telecare ZXT427

Страница 1: ... behind a curtain directly above the cooker or sink next to a door or window or near an extractor fan The combined gas CO detector should be within 5 metres of a mains supply otherwise the cable provided will need extending Typical Tools Required Be careful when using step ladders always face the direction you are working Always make sure the correct drill bits and screwdrivers are used Installati...

Страница 2: ...alified person to find the cause of the alarm If the alarm continues turn the appliance off and do not use until it has been checked by a qualified person Get medical help for anyone suffering headaches or nausea advise that carbon monoxide poisoning is suspected In Case of Fault If the YELLOW FAULT light illuminates the self test feature has detected a fault with the sensor The unit is probably d...

Страница 3: ...ter the Beep press to exit Press the key to exit Program Mode the unit will sound a Double Beep and the front light will return to STEADY GREEN Both 8 digit ID s can be found on a label on the back of the gas CO detector they will always start with 44xxxxxx and 49xxxxxx The instructions given above for the standard Reach product also applies to the Reach Plus Reach Plus GSM and Reach Ultra models ...

Страница 4: ...ndant Disabled Enter Flat prompt Press the key and wait for the Ready prompt then press the LINE key to clear the connection Refer to the Advent xt operators manual Doc No FM0420 provided with the warden call system for more information on programming and testing radio devices Using the Manager s DECT telephone Press the LINE key and wait for the Ready prompt Enter 5 0 0 0 followed by the key Ente...

Страница 5: ...mode select Exit then press the ENTER key Refer to the Altec Response installation guide Doc No FM0548 provided with the portable alarm unit for more information on programming and testing radio devices Press the TRANSMIT GAS button once The display will show Gas Alarm and the gas detector 8 digit ID number Check the ID is correct press the key to select Accept then press ENTER Note if another dev...

Страница 6: ...Delete Telecare Device pull down list box prefixed T49 and repeat as above Press the Close button to exit Refer to the Touchsafe Pro Display Panel user guide Doc No FM5505 provided with the Nursecall system for more information Tynetec and Aidcall operate a policy of continuous improvement and reserve the right to change product specifications without notice If any variation to the details contain...

Отзывы: