PP3 BATTERY

We declare this product complies with the relevant UK 
legislation on condition that it is used in the manner 
intended, and in accordance with the current installation 
standards and/or the manufacturer's recommendations. 
A copy of the full UKCA Declaration of Conformity is 
available on request.

 

Mask Time & Battery Test 

 

The Enuresis sensor transmitter has a 15 minute mask time to prevent the same alarm  
call re-reporting several times. There is a facility for Engineers to override this mask  
time and test the battery at the same time.  

 

When the sensor is activated the alarm call will be transmitted once, no further  
transmissions will occur for 15 minutes giving time for the cause to be cleared. 

 

Engineer’s

 mask reset function; open the case, press and hold 

BUTTON 1 

on the transmitter  

for 2 seconds until the 

RED

 light flashes once. After a short delay the 

RED

 light will flash once more  

to indicate the mask time is reset and the battery power is OK. If the 

RED

 light flashes several times the battery power is low. 

 

 
 

Maintenance 

 

The Enuresis sensor should be activated periodically to check the bed mat is functioning and verify operation. 

 
 

Cleaning the Bed Mat 

 

To prevent false alarms always un-plug the bed mat from the interface unit before cleaning.  
The bed mat can be wiped clean with a damp cloth and soapy water or a mild disinfectant. 
Do not fully submerge the bed mat lead or interface unit in water. 

 
 

 

Replacement Bed Mats 

 

Due to the nature of the product bed mats are non-returnable.  
Replacement mats are available separately 

 order Tynetec Part No. W00369.

 

 
 

Battery Life 

 

The battery is checked once a day, if the voltage falls and stays below a pre-set level for 7 consecutive days a low battery alert is 
automatically transmitted. Once a low battery call is received the battery should be replaced within 7 days. 

 

Detailed information on battery management for all Tynetec/Aidcall products is available - request Doc No. FM0630.

 

 
 

Battery Replacement 

 

Slide the battery compartment cover off the rear 
of the interface unit. 

 

Disconnect the old battery and replace with an 
identical type; 

9V Duracell Plus MN1604

 

Refit the battery compartment cover. 

 

Perform a test call to check the new battery is  
fitted and working correctly.   
 
 
 
 
 
 
 

 

Declaration of Conformity

 

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 

SLIDE THE COVER OFF 
TO REVEAL THE BATTERY 

9 Volt 

Battery 

PRESS AND HOLD

 

BUTTON 1

 

TO RESET 

THE MASK TIME

 

 

THE 

RED

 LIGHT  

WILL FLASH

 

 

We declare this product complies with the relevant 
European legislation on condition that it is used in the 
manner intended, and in accordance with the current 
installation standards and/or the manufacturer's 
recommendations. A copy of the full CE Declaration of 
Conformity is available on request.

 