background image

 
 
 

 

SRC Quick Setup Guide 

SRC_QSG_A1_4.0.10 

 255-80-0063-00 RoHS 

 
 
 
 

 

Smart Rack Controller® SRC-0100, SRC-0102, SRC-0103, SRC-0800, SRC-0803 

Thank you for purchasing Raritan's Smart Rack Controller (SRC). This product provides an ideal rack management solution which features the 
following functions for data centers and server rooms: 

 

Support for environmental sensors: https://www.raritan.com/products/power/rack-management/smart-sensors   

 

Control and detection of cabinet doors: https://www.raritan.com/products/power/rack-management/smartlock-door-access-control 

 

Asset management: https://www.raritan.com/products/power/rack-management/asset-management-solution 

Note: Some models do not support using asset management and SmartLock simultaneously. 

For more, access online help from the web interface or go to Raritan's 

Support page

 (

www.raritan.com/support

)

 

SRC-0100, SRC-0102, SRC-0103, SRC-0800, SRC-0803 

 

Package Contents 

The following lists the equipment shipped with SRC. If anything is 
missing or damaged, contact the local dealer or Raritan Technical 
Support for help. 

 

One SRC device 

 

Bracket pack and screws 

 

Quick Setup Guide 

 

Optional Accessories 

Optional accessories shipped on demand only. 

 

Asset management strips and asset tags 

 

Door handles or SmartLock kit 

 

Environmental sensor packages, DX or DX2 series 

 

Sensor hubs 

 

QS Rule  

 

Before You Begin 

Prepare the installation site. Make sure the installation area is clean 
and not exposed to extreme temperatures or humidity. Allow 
sufficient space around the SRC for cabling and equipment 
connections. 

 

QS Rule  

 

Rackmount 

There are two ways to mount an SRC device, using the same 
Raritan rackmount brackets. 

 

 

1U Rackmount Method 

 

 

To mount SRC like a 1U device: 

1.

 

Align the two edge slots of the L-bracket with two of the screw 
holes on one end of the SRC device. 

2.

 

Screw the L-bracket to the device and ensure the bracket is 
fastened securely. 

 

3.

 

Repeat Steps 1 to 2 to screw another L-bracket to the other end 
of the device. 

4.

 

After both L-brackets are installed, fasten the device to the 
rack, using rack screws, through two identical round holes of 
each L-bracket. 

 

QS Rule  

 

0U Rackmount Method 

 

QUICK SETUP GUIDE 

 

Содержание Raritan Smart Rack Controller SRC-0103

Страница 1: ...is missing or damaged contact the local dealer or Raritan Technical Support for help One SRC device Bracket pack and screws Quick Setup Guide Optional Accessories Optional accessories shipped on demand only Asset management strips and asset tags Door handles or SmartLock kit Environmental sensor packages DX or DX2 series Sensor hubs QS Rule Before You Begin Prepare the installation site Make sure ...

Страница 2: ...TURE port red AMS series asset management strips Refer to FEATURE 3 below SRC models Connection ports Supported accessories SRC 0800 SRC 0803 Sensor 1 Sensor 8 DX2 sensors or actuators Refer to FEATURE 4 below SRC 0800 SRC 0803 Remote Hub 1 Remote Hub 2 DX2 REMHUB4 sensor hub Refer to FEATURE 5 below QS Rule FEATURE 1 Support for DX and DX2 Environmental Sensors Actuators DX or DX2 environmental s...

Страница 3: ... length for door handles or SmartLock kit is 29 feet 9 meters For details refer to the following diagram Connecting a SmartLock Kit to DX2 DH2C2 You need a SmartLock kit if your SRC does NOT include a built in DX2 DH2C2 such as SRC 0100 SRC 0800 and SRC 0803 DX2 DH2C2 ports and terminals No Component Function Two pairs of contact closure sensor terminals Connect to third party contact closure dete...

Страница 4: ...u can attach asset strips up to 64U long consisting of one PRIMARY and multiple EXPANSION asset strips The difference between the primary and expansion asset strips is that the primary asset strip has an RJ 45 connector while the expansion does not The following diagram illustrates some asset strips Not all available types are pictured 8U PRIMARY asset strip with 8 tag ports 8U EXPANSION asset str...

Страница 5: ...port on the asset strip 3 AMS series asset strips AMS M8 AMS S8 and AMS E 2 8 Connect the primary asset strip s RJ 45 connector to the FEATURE port using a network patch cable CAT5e or higher A Primary asset strip B Asset tags C IT devices QS Rule Other Types of Asset Strips Blade extension strips For blade servers which are contained in a single chassis you can use a blade extension strip to trac...

Страница 6: ...t subnets If you are not sure whether the device is connected to the same or different subnets contact your IT department To make a wireless connection 1 Connect an appropriate USB wireless LAN adapter to the SRC 2 Make sure the wireless LAN configuration is supported by your SRC See Wireless LAN Information QS Rule Using a Web Browser Step 1 Retrieve the IP Address After connecting to a DHCP IPv4...

Страница 7: ...ate login credentials PDView automatically logs in to the web interface of SRC If PDView can t login automatically the login screen displays instead and you must enter appropriate user credentials for login 4 For initial login you are prompted to change the password QS Rule Appendix B Wireless Configuration USB Wireless LAN Adapters The SRC supports the following USB Wi Fi LAN adapters Wi Fi LAN a...

Страница 8: ...r more information about SRC and the entire Raritan product line see Raritan s website www raritan com For technical issues contact Raritan Technical Support See the Contact Support page in the Support section on Raritan s website for technical support contact information worldwide Raritan s products use code licensed under the GPL and LGPL You can request a copy of the open source code For detail...

Отзывы: