background image

 
 
 

 

PXC_PXO Quick Setup Guide 

PXC_PXO_QSG_A1_4.0.10 

 255-80-0059-00 RoHS 

 
 
 
 

 

     

4.

 

Repeat the same steps to install the other button onto the PDU's rear side. 

 

5.

 

Properly install the PDU by fitting the attached rear buttons into position of the rack. 

a.

 

Press the PDU toward the rack. 

b.

 

Push the mounting buttons through the mounting holes. 

c.

 

Let the PDU drop slightly. 

 

Mounting Zero U Models with Screw Buttons 

1.

 

Turn to the rear of the PXC. 

2.

 

Locate the two screw holes on the rear panel. 

3.

 

Screw a button in each screw hole. The recommended torque for the button is 1.96 N·m (20 kgf·cm). 

       

 

4.

 

Press the PDU forward, pushing the mounting buttons through the mounting holes, then letting the PDU drop slightly. 

 

Mounting 1U or 2U Models 

Using the appropriate brackets and tools, fasten the 1U or 2U PXC PDUs to the rack or cabinet. 

Содержание PX2

Страница 1: ...duct in a dry location WARNING Connect this product to a protective earth ground Never use a ground lift adaptor between the product s plug and the wall receptacle WARNING If this product is a model that requires the assembly of the line cord or plug the assembly must be performed by a licensed electrician and the line cord or plugs used must be rated based on the product s nameplate ratings as we...

Страница 2: ...vice connected to the PDU s power outlets QS Rule Mounting the PDU Use one of the mounting methods to install your product Circuit Breaker Orientation Limitation Usually a PDU can be mounted in any orientation However when mounting a PDU with circuit breakers you must follow these rules Circuit breakers CANNOT face down For example do not horizontally mount a Zero U PDU with circuit breakers facin...

Страница 3: ...rough the mounting holes c Let the PDU drop slightly Mounting Zero U Models with Screw Buttons 1 Turn to the rear of the PXC 2 Locate the two screw holes on the rear panel 3 Screw a button in each screw hole The recommended torque for the button is 1 96 N m 20 kgf cm 4 Press the PDU forward pushing the mounting buttons through the mounting holes then letting the PDU drop slightly Mounting 1U or 2U...

Страница 4: ...o both sides of the PXC with the provided screws 2 Attach PXC to the rack Fasten the rackmount brackets ears to the rack using your own fasteners PXO Rackmount Method You can place PXO in any appropriate location with or without fastening it To fasten it simply screw up fasteners to screw holes on two sides of PXO QS Rule ...

Страница 5: ...r or both Ethernet ports on the PXC PXO 2 Connect the other end of the cable to your LAN Note If connecting both ports to the LAN you must connect them to two different subnets If you are not sure whether the device is connected to the same or different subnets contact your IT department To make a wireless connection 1 Connect an appropriate USB wireless LAN adapter to the PXC PXO 2 Make sure the ...

Страница 6: ...ttings 4 To change network settings choose Device Settings Network Tip You can enable both wired and wireless networking so that the PXC PXO can be accessed via either wired or wireless IP address 5 PXC PXO is sent from the factory with all the outlets ON If your model is outlet switching capable turn OFF the outlets without devices connected 6 Use the menu to the left to configure user profiles p...

Страница 7: ...DView on your mobile device 2 Wait until PDView detects the connected PXC PXO and shows the word Connected in green 3 If the factory default login credentials remain unchanged or if PDView has been configured with accurate login credentials PDView automatically logs in to the web interface of PXC PXO If PDView can t login automatically the login screen displays instead and you must enter appropria...

Страница 8: ...n Plug a supported USB wireless LAN adapter into the USB A port on your PXC PXO OR Connect a USB hub to the USB A port on the PXC PXO Then plug the supported USB wireless LAN adapter into the appropriate USB port on the hub QS Rule Appendix C More Information Disconnecting Devices from Locking Outlets Not every PXC PXO is implemented with locking outlets Locking outlets if available on your PXC PX...

Страница 9: ...d the entire Raritan product line see Raritan s website www raritan com For technical issues contact Raritan Technical Support See the Contact Support page in the Support section on Raritan s website for technical support contact information worldwide Raritan s products use code licensed under the GPL and LGPL You can request a copy of the open source code For details see the Open Source Software ...

Отзывы: