LEGRAND Pass & Seymour OSR300S Скачать руководство пользователя страница 8

Limited FIVE YEAR Warranty

Pass & Seymour/Legrand will remedy any defect in workmanship or material in Pass & Seymour/Legrand prod-

ucts which may develop under proper and normal use within five years from the date of purchase by a consumer:
(1) by repair or replacement, or, at Pass & Seymour/Legrand’s option, (2) by return of an amount equal to the con-

sumer’s purchase price. Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour/Legrand does

not include or cover cost of labor for removal or reinstallation of the product. ALL OTHER FURTHER ELEMENTS OF

DAMAGE (INCIDENTAL OR CONSEQUENTIAL DAMAGES) FOR BREACH OF ANY AND ALL EXPRESSED OR IMPLIED

WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE

EXCLUDED HEREBY. (Some states do not allow disclaimer or exclusion or limitation of incidental or consequential

damages, so the above disclaimers and limitation or exclusion may not apply to you.) ANY IMPLIED WARRANTIES

INCLUDING WHERE REQUIRED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

SHALL BE LIMITED TO THE FIVE YEAR PERIOD SET FORTH ABOVE. (Some states do not allow limitation on how

long an implied warranty lasts, so the above limitation may not apply to you.)
To ensure safety, all repairs to Pass & Seymour/Legrand products must be made by Pass & Seymour/Legrand or

under its specific direction. Procedure to obtain performance of any warranty obligation is as follows: (1) Contact

Pass & Seymour/Legrand, P.O. Box 4822, Syracuse, NY 13221 for instructions concerning return or repair; (2) return

the product to Pass & Seymour/Legrand, postage paid, with your name and address and a written description of the

installation or use of the Pass & Seymour/Legrand product, and the observed defects or failure to operate, or other

claimed basis for dissatisfaction.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

P.O. Box 4822, Syracuse, NY 13221-4822

Technical Support: 800.223.4185 • www.passandseymour.com

340784 Rev. B 07927

ORDERING INFORMATION

Units come in White (-W), Ivory (-I), Gray (-GRY) and Light Almond (-LA).
Add color designator to catalog number when ordering.

Catalog #

Description

OSR300S

Universal PIR Wall Switch; 120/277VAC, 50/60Hz

Lights do not turn off

1. There can be up to a 30 minute time delay after the last motion is

detected. To verify proper operation, set DIP switch 1 to ON, then reset
switches 1, 2, and 3 to OFF to start Test Mode. Move out of view of the
sensor. The lights should turn off in approximately 15 seconds. Relay 2
lights turn off 10 seconds after Relay 1 lights, if DIP switch 4 is ON.

2. Verify that the sensor is mounted at least six feet (2 meters) away from

any heating/ventilating/air conditioning device that may cause false
detection. Verify that there is no significant heat source (e.g., high wattage
light bulb) mounted near the sensor.

3. If the lights still do not turn off, call 800.223.4185 for technical support.

Sensing motion outside desired areas

1. Select Sensitivity – Low (DIP switch 8 = ON) if necessary.
2. Mask the sensor’s lens, using the opaque tape supplied.

No response to repeated button presses

Rapid pressing of the Auto-ON/OFF button causes a delay in proper
functioning of the sensor. If the sensor does not respond to pressing the
ON/OFF button, wait 10-15 seconds, then press the button

once

again.

Содержание Pass & Seymour OSR300S

Страница 1: ...Horsepower Rating each relay 1 6 HP Time Delay Adjustment 5 to 30 minutes Walk Through Mode 3 minutes if no activity after 30 sec Test Mode 15 sec upon initial power up or DIP switch reset PIR Sensit...

Страница 2: ...ither Auto On or Manual On In either mode the load can be turned on or off using the ON OFF button Auto On Load turns on and off automatically based on occupancy If the load is turned off manually aut...

Страница 3: ...cancels automatically after five minutes or if a fixed time delay is selected To reenable the Test Mode for an additional five minutes change the time delay from any fixed amount to the SmartSet Test...

Страница 4: ...wing Fresnel lens with 180 degree field of view Masking the lens Opaque adhesive tape is supplied so that sections of the sensor s view can be masked This allows you to eliminate coverage in unwanted...

Страница 5: ...n Wait one minute then push the Auto ON OFF switch for each load and the lights will turn on There is a delay due to initial power up of the sensor that only occurs during installation Screw Terminal...

Страница 6: ...N OFF 6 Auto On Manual On Relay 2 ON Mode 4 Use Relay 1 Delay Add 10 minutes Delay Relay 2 Disconnect 1 2 3 4 5 6 7 8 Time Delay FACTORY PRESETS Delay Relay 2 Disconnect ON Relay 1 On Mode Relay 2 On...

Страница 7: ...follow the directions below All major adjustments to the OSR300S must be made with the wall plate removed To access the DIP switches remove the button cap by squeezing the top sides of the button asse...

Страница 8: ...eturn or repair 2 return the product to Pass Seymour Legrand postage paid with your name and address and a written description of the installation or use of the Pass Seymour Legrand product and the ob...

Отзывы: