Disc. Settings 
 

The Discovery Settings option, selected from the Installer Setup screen (see 

Figure 42

) is an 

option screen that allows the installer to turn ON the unit beep that occurs when units are 
discovered. It is turned OFF by default (see 

Figure 43

) so as not to disturb homeowners at 

night if there is a temporary power outage and restoration of power. When turned ON, each unit 
in the system will beep as it is discovered upon power initialization. 
 
 
 
 
 
 
 
 
 
 
 
 
 

Room Options 
 

The Room Options Installer Setup option, selected from the Installer Setup screen (see 

Figure 

44

) is an option screen that allows the installer to adjust the contrast of the Room Unit’s LCD 

display. This option is set at the factory (see 

Figure 45

) and should not need to be adjusted, 

but if desired, press the talk/select button, and use the up/down arrow buttons to adjust the 
contrast of the display to taste.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 42 

Figure 43 

ROOM1

INSTALLER SETUP

Reply Options

Door Options

Firmware Info
System Reset

Room Options

Disc. Settings

ROOM1

INSTALLER SETUP

Reply Options

Door Options

Firmware Info
System Reset

Room Options

Disc. Settings

ROOM1

DISC. OPTIONS

Discovery Beep:

BACK

OFF

ROOM1

DISC. OPTIONS

Discovery Beep:

BACK

OFF

Figure 44 

Figure 45 

ROOM1

INSTALLER SETUP

Reply Options

Door Options

Firmware Info
System Reset

Room Options

Disc. Settings

ROOM1

INSTALLER SETUP

Reply Options

Door Options

Firmware Info
System Reset

Room Options

Disc. Settings

ROOM1

ROOM OPTIONS

Contrast

Contrast

BACK

>

Contrast

ROOM1

ROOM OPTIONS

Contrast

Contrast

BACK

>

Contrast

Содержание ON-Q IC5002-OB

Страница 1: ...i 301 Fulling Mill Road Suite G Copyright 2008 by On Q Legrand Middletown PA 17057 Inc All Rights Reserved 800 321 2343 www onqlegrand com Selective Call Intercom SYSTEM INSTALLATION GUIDE 1308003 RE...

Страница 2: ...ERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE INSTALLATION AND TROUBLESHOOTING INSTRUCTIONS REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION THIS DEVICE MUST BE INSTALLED AND USED IN...

Страница 3: ...nts 2 III Wiring Specifications 3 A Specifications 3 B Guidelines 3 C Unit Placement 3 D Termination Instructions 3 IV System Wiring Overview 4 A Pre Wiring Rough In 4 B Final Wiring Trim Out 7 V Syst...

Страница 4: ...Page iv 301 Fulling Mill Road Suite G Copyright 2008 by On Q Legrand Middletown PA 17057 Inc All Rights Reserved 800 321 2343 www onqlegrand com...

Страница 5: ...the term component will be used to indicate one or all of the following Intercom Module Room Unit Patio Unit or Door Unit These installation instructions were designed for use by an authorized On Q i...

Страница 6: ...ed monitor and mute and advanced functions such as dynamic sorting of users or monitoring multiple rooms at the same time Up to 8 Selective Call Room Units can be installed per Selective Call Intercom...

Страница 7: ...bling runs at both ends Use the distance between your hand and your elbow as a guide to determine how far from the end of the cable to place the label C Unit Placement To provide optimal display quali...

Страница 8: ...cavity on opposite sides of the wall to prevent feedback problems If Room Units must be mounted back to back place insulation in the back of both electrical boxes The Room Unit mounts in a standard 2...

Страница 9: ...t be provided with specific instructions as to how the 2 gang box should be installed including location correct positioning and proper depth If possible clearly mark this information on the home s ex...

Страница 10: ...ed including location correct positioning and proper depth If possible clearly mark this information on the home s exterior insulation board or vapor barrier material to serve as a reminder to the mas...

Страница 11: ...oom Unit s is as follows Locate a Cat 5e cable in a roughed in 2 gang box labeled as Room Unit X X is the Room Unit number Strip approximately 2 of insulation from the Cat 5e cable Untwist cable pairs...

Страница 12: ...tep NOTE There are slotted holes in the mounting bracket to allow for leveling of the Patio Unit in case the gang or back box was installed off level Use the four provided screws to attach the mountin...

Страница 13: ...lled off level Use the four provided screws to attach the mounting bracket to the gang or back box Pull the Cat 5 cable from the enclosure through the mounting bracket and terminate the cable with an...

Страница 14: ...tion Module These are Open Collector outputs labeled A and B ground and output connectors for each At any Room Unit you can configure the A Door Strike Release and or B Alert Trigger outputs to be ena...

Страница 15: ...nd verify system functionality All Selective Call Room Door and Patio Units will be discovered see Figure 14 and shown on each Room Unit LCD see Figure 15 ROOM1 ROOM2 ALL PATIO1 SETTINGS DOOR1 ROOM1 R...

Страница 16: ...name see Figure 20 Attic Dock Kid s Room Office 4 Baby s Room Entertain Rm Kids Room 2 Office 5 Balcony Family Room Kids Room 3 Office 6 Bar Foyer Kids Room 4 Office 7 Basement Front Desk Kitchen Offi...

Страница 17: ...ing those button functions may be disabled or enabled at that particular Room Unit Figure 25 shows that you can also determine the period of time of inactivity 1 minute default 5 minutes or 10 minutes...

Страница 18: ...ng Chime 4 Westminster Short Chime 5 Two Note Ding Dong Chime 6 Two Note Dong Ding Chime 7 Jetson s Doorbell Chime 8 Eastern Strings Ethnic 9 Calypso Party Ethnic 10 F r Elise Classical 11 Beethoven s...

Страница 19: ...re typically configured only at the time of system installation or options that are used for system update or reset Select Installer Setup from the Settings screen see Figure 34 to see a list of all t...

Страница 20: ...s Disc Settings Reply Options REPLY OPTIONS 10 sec Door Reply BACK REPLY OPTIONS 10 sec Door Reply BACK Figure 36 Figure 37 ROOM1 INSTALLER SETUP Reply Options Door Options Firmware Info System Reset...

Страница 21: ...t allows the installer to adjust the contrast of the Room Unit s LCD display This option is set at the factory see Figure 45 and should not need to be adjusted but if desired press the talk select but...

Страница 22: ...et a Room Unit screen similar to the one shown in Figure 53 will be seen FIRMWARE INFO Unit Name Address 90 1040 Rev v1 0rc2 28 BACK ROOM 4 FIRMWARE INFO Unit Name Address 90 1040 Rev v1 0rc2 28 BACK...

Страница 23: ...fault Room Options Room Volume 75 LCD Brightness 90 Chime Volume 75 Monitor ON Mute ON Theme Theme 1 Time Out 1 minute Sort Dynamic Default Door Options Chime Chime 1 Volume 70 Chime Volume 75 Default...

Страница 24: ...ntercom Module Verify that your terminations follow the T568A wiring standard If your wiring terminations are visibly correct according to the T568A standard test the conductivity of the connections a...

Страница 25: ...ed On Q name or logo and Customer by acceptance of the product agrees that its sole and exclusive remedy shall be against the manufacturer of such product The foregoing warranty for Warranted Products...

Страница 26: ...2 3 4 Room 4 New name FW rev Address Sort D A Mute On Off Mon On Off T O 1 5 10 Theme 1 2 3 4 Room 5 New name FW rev Address Sort D A Mute On Off Mon On Off T O 1 5 10 Theme 1 2 3 4 Room 6 New name F...

Отзывы: