Mallia™
2810 91
2812 91
2814 91
2816 91
●
Time Delay Switch
N 63174A
Utilization
Important: If the wiring diagrams are not strictly followed, or if the values shown in the table are
exceeded (voltage, power, temperature, frequency), or if the power is too low and causes
the light to blink, the switch would be severely damaged.
Min
Max
25W
1000W
25W
1000W
NO
NO
NO
NO
NO
NO
➀
➁
➂
➃
➄
➅
➆
➇
1. Incandescent lamps
2. 230V Halogen lamps
3. Fluorescent lamps ø26mm or ø38mm (forbidden)
4. Halogen lamps with electronic ballast (forbidden)
5. Motors (forbidden)
6. Halogen lamps with ferromagnetic transformer (forbidden)
7. Ferromagnetic transformer (forbidden)
8. Additional radiators (forbidden)
N.B
: These values to be reduced by 20% per
temperature band of 10℃ above 25℃.