LEGRAND lyriQ Скачать руководство пользователя страница 6

 

 
 
 
 
 
 
301 Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 321-2343 / Fax (717) 702-2546 
www.onqlegrand.com

 

 

 

 

 

 

 

 

 

 

 

 

 

                  

 

 

Page 6 of 8

 

INSTRUCTION/INSTALLATION SHEET 
lyriQ™ Standard Keypad

 

IS-0391 REV. E

 

  ©Copyright 2009 by Legrand All Rights Reserved. 

 

 

 

6.   lyriQ™ Keypad Installer Settings Reference Guide   
 

AU5009-xx

 lyriQ Standard Keypad in Studio, 

AU5010-xx

 lyriQ High Performance Keypad in Studio, 

AU7394-xx

 lyriQ 

Standard Keypad, 

AU1000-xx

 lyriQ High Performance Keypad 

 

 
Setting 
 

 
Function 

 
Use Case 

 
Enter Installer 
Setting Mode 

 
Puts keypad into installer setting mode so that keypad 
can be customized to environment and customer 
preferences. 
 

To implement:

 quickly press keys in the following 

sequence: Mute, Volume Up, Volume Down, Volume 
Down. Repeat.  
 

Note: The sequence needs to be done twice. 

 

 
To enter into installer settings so that keypads 
can be personalized for the user and to their 
environment.  

 
Whole House: 
Enable/Disable 

 
Default

 (src 1, vol. 1) The local keypad will respond 

and be able to be controlled from other keypads on the 
system that have engaged Whole House Mode.  
 

Whole House Disable 

(src 1 vol.2)

 

turns off the ability 

of a keypad to be controlled by other keypads that 
have engaged Whole House Mode. Will not respond to 
audio interrupt. Will still be able to implement a Whole 
House command from keypad. 
Keypads connected to systems with the Integration 
Module will not be controlled by Integration Module 
communications. 
 

Note

This is set on each keypad, not globally.

 

 

Default 

is used for normal operation and 

environments. 

 
 
Whole House Disable 

is typically used for 

outdoor spaces, baby’s rooms, offices or other 
areas that should not be disturbed.

 

 
Turn-On Volume  

 
Default

 (src 2, vol. 1) turn on volume is about 10% full 

volume. 
 

Turn-On Volume  
 

-

 

Variable turn on volume

: (src 2, vol. 

adjust to 

desired level

) enables a standard turn on volume 

to be selected from 0% - 50% of full volume. 
 

-

 Last 

volume

: (src 2, vol. 5) turn on volume will 

be set at the volume that the user left the keypad 
at before it was turned off. 
 
 
 
 

Default 

is used for normal operation and 

environments. 
 

Turn-On Volume

 allows installer to customize 

the volume level to the homeowner’s 
environment and preference. 

Содержание lyriQ

Страница 1: ...EDs SOURCE with four green Source Selection LEDs and MUTE with one red status LED There is also an IR target window and tri colored status LED The rear of the lyriQ Standard Keypad see Figure 2 contai...

Страница 2: ...jack J1 see Figure 2 2 For the Line Out Speakers Out connections TB1 TB2 strip 3 8 of insulation from each of the four conductors and insert the appropriate wires into the appropriate connections see...

Страница 3: ...e 8 Zone Module cascade Single Source Modules To cascade a Single Source Module simply run a Category 5 jumper from the Cascade Out RJ45 jack on the front panel of the first Module to the Source In RJ...

Страница 4: ...wait for 10 second time out see Figure 5 NOTE When any Keypad button is tapped back light level goes to full bright and returns to the adjusted level when activity ceases For Remote operation the back...

Страница 5: ...nd then 2 and finally to 3 while double tapping it will cause every active keypad to go directly to Source 3 NOTE The Whole House Source Control mode will be exited when the user fails to press a key...

Страница 6: ...controlled from other keypads on the system that have engaged Whole House Mode Whole House Disable src 1 vol 2 turns off the ability of a keypad to be controlled by other keypads that have engaged Who...

Страница 7: ...of radiated interference IR Target Disabled for use when system is installed in environments that have extreme levels of radiated interference Nightlight Default src 1 3 vol 1 Keypad glows dimly when...

Страница 8: ...al source which requires a change Auto Off Enable Disable Default src 2 4 vol 1 Keypad will turn off after 20 minutes of no music Auto Off Disable src 2 4 vol 2 Keypad will remain on until manually tu...