Wiring diagram for Series 7 entry panel

Extensions

Up to four handsets for the same call.

For two, three or four handsets, multiply the cross-sections by two, three or four (1E,2,9,10).

Accessory

Connection of an electric rim lock to entry panel using an AC power supply only.

2 3 4 5

1E

P

P

1Z

2 3 4 5

1E

P

P

1Z

Series 7 entry panel

Series 7

Series 7

Series 7 entry panel

11

CP76
Relay Rectifier Board

OUT

OUT

10

10

9

Rim Lock

IN

IN

Series 7

2 3 4 5

1E

P

P

1Z

2 3 4 5

1E

P

P

1Z

Pn

P1

9

10

3

4

5

9

10

2
3
4
5

P

4

P

2

P2

P4

3

4

5

P

2

P

4

P

6

P

8

9

10

10

11

P

1

P

3

P

5

P

7

See note 1

12V DC Power Supply
Note polarity

Series 7 entry panel

Series 7

* Do not connect door strike / rim lock to entry panel as shown if a DC supply is powering the unit.

See note 2

See note 2

See note 2

See note 3

S

e

e

 n

o

te

 4

or

SITUATION: 
1. Wiring diagram for Series 7 where the gate/door release operates an electric door strike, rim lock or magnetic lock and the power supply 

is 12V DC.

NOTE 1

 Select the chime type in the sound unit.

                       Left jumper: electronic

NOTE 2 

 p1, p2…pn are the call lines to the 

handset(s) in each apartment / house. With an 
apartment system each apartment will typically have a 
dedicated call line. 

P1 = top right hand call button of a call button panel 
(viewed facing the front of the panel)
P2 = top left hand call button etc

NOTE 3 

 For pre-impulsed electric locks set timer to 1 

second. Refer to separate  CP79v2 instruction leaflet.

NOTE 4 

 Use N/C contact for magnetic lock and set 

timer to suit. 

10

11

10

11

P

3

P

1

P1

P3

TR

G

-

-

-

CO

M

N/

C

N/

O

RS

T

CP79v2 Pulse Stretcher

Rimlock

Содержание LEGD365 061

Страница 1: ...mmunication between the handset and entry panel can take place If at the same time any other handset is lifted off its cradle there will be common communication with the first handset and the entry pa...

Страница 2: ...ERNATIVELY Table of recommended cross sections 2 4 n 5 2 5 5 5 4 n 2 4 n 4 OR 12V DC Power Supply only Door strike or Gate release CP13E 12V Power supply NOTES 1 A door strike can only be connected di...

Страница 3: ...onnected directly to the entry panel as shown if an AC supply is powering the unit NOTE 4 p1 p2 pn are the call lines to the handset s in each apartment house With an apartment system each apartment w...

Страница 4: ...lock and the power supply is 12V DC NOTE 1 Select the chime type in the sound unit Left jumper electronic NOTE 2 p1 p2 pn are the call lines to the handset s in each apartment house With an apartment...

Страница 5: ...cessory Connection of an electric rim lock to entry panel using an AC power supply only 2 3 4 5 1E P P 1Z 2 3 4 5 1E P P 1Z Series 7 entry panel Series 7 Series 7 Series 7 entry panel 11 CP76 Relay Re...

Страница 6: ...n backing piece from the facia Insert the label and replace the plastic backing piece 11 Clip the module back onto the facia 15 Hinge open the entry panel and terminate the wiring referring to the wir...

Страница 7: ...k Larsen effect The lock must be powered Check in the entry panel that Adjust the volume in the entry panel 4 None of the handsets sound reaches the entry panel the voltage is approx 12 V AC between t...

Страница 8: ...860 CENTURION FOR TECHNICAL SUPPORT CONTACT JOHANNESBURG CENTRAL WR 011 699 2400 JOHANNESBURG EAST RAND 011 397 6401 PRETORIA 012 362 8819 8893 VEREENIGING 016 422 5667 NELSPRUIT 013 752 8074 5 DURBAN...

Отзывы: