25
KEOR MULTIPLUG
600 VA - 800 VA
EN
4.3
Shutdown
1. Press and hold the ON/OFF button until the blue led turns off.
2. The UPS stops powering the back-up outlets.
3. Unplug the UPS from the mains power supply socket to stop powering also the overvoltage
protected outlets.
4.4
LED and Alarm Indicators
NORMAL MODE/
BATTERY MODE LED
ALARM
LED
ALARM
UPS STATUS
Steady
OFF
OFF
The UPS is operating in normal mode
LED blinking every 3
seconds
OFF
OFF
UPS operating in battery mode with
battery status 40%-100%
LED blinking every 3
seconds
OFF
1 beep every 10
seconds
UPS operating in battery mode with
battery status 20%-40%
LED blinking every 2
seconds
OFF
1 beep every 2
seconds
UPS operating in battery mode with
battery status <20%
Steady
OFF
Intermittent
Overload in normal mode
OFF
Steady
Continuously
sounding
UPS shutdown due to prolonged
overload
Steady
Steady
1 beep every 10
seconds
Battery fault
OFF
Steady
Continuously
sounding
UPS fault (other than overload)
Содержание KEOR MULTIPLUG 600 VA
Страница 1: ...Part LE10562AA 02 18 01 GF KEOR MULTIPLUG 600VA 800VA Manuel d installation Installation manual ...
Страница 8: ...8 3 Installation ...
Страница 16: ...16 ...
Страница 22: ...22 3 Installation ...
Страница 30: ...30 ...
Страница 36: ...36 3 Installazione ...
Страница 44: ...44 ...
Страница 50: ...50 3 Installation ...
Страница 58: ...58 ...
Страница 64: ...64 3 Instalación ...
Страница 72: ...72 ...
Страница 78: ...78 3 Монтаж ...
Страница 86: ...86 ...
Страница 87: ...87 ...