INSTALLATION INSTRUCTIONS

LPS_F-5290_090418

4.  After the Drywall has been installed, cut a rectangular hole ( recommended hole 3-3/8" x 9" ) and insert the 

mounting-housing making sure that the hooks on housing are pointing up. Attach housing to back-box using 
the four (4) 1.5" screws provided with the fixture.

Brackets

Hanger bars

Back-box

Knockout

Screws

a-b

c

Studs

Screws 
(Supplied 
by others)

3.  Mount Back-box and Hanger Bars. 

a.  Remove knockouts as needed.
b.  Mount back-box to hanger bars using the screws and brackets supplied with the fixture.
c.  Install hanger bar assembly. Use four screws per hanger bar (supplied by others).

Note: Remember to use non-ferrous hardware when installing MRI fixtures.

Back-box

Cutout

Drywall

Drywall

Hooks

1.5" Screws

Mounting-Housing

3.375

9.000

Содержание Kenall LOW PROFILE SCONCE LPS Series

Страница 1: ...ODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE INSTALL IN ACCORDANCE WITH ALL NATIONAL STATE AND LOCAL CODES DO NOT CONNECT TO AN UNGROUNDED SUPPLY READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF ...

Страница 2: ...n installed cut a rectangular hole recommended hole 3 3 8 x 9 and insert the mounting housing making sure that the hooks on housing are pointing up Attach housing to back box using the four 4 1 5 screws provided with the fixture Brackets Hanger bars Back box Knockout Screws a b c Studs Screws Supplied by others 3 Mount Back box and Hanger Bars a Remove knockouts as needed b Mount back box to hange...

Страница 3: ...shielded room Follow recommended wiring layout described below All wiring must be within completely enclosed grounded conduit suitable for an MRI environment Any gaps regardless of size must be closed or wrapped in copper foil tape Special attention should be paid to the wiring entry point into the shielded space Class 1 wiring methods are required c Run the dimming signal wiring equal in specific...

Страница 4: ...ntent of specification sheets is subject to change please consult www kenall com for current product details 2019 Kenall Mfg Co 4 INSTALLATION INSTRUCTIONS LPS_F 5290_090418 Mounting Hooks Top of housing No hole Screw 6 Install fixture Top of housing over top of housing s hooks 7 Tighten screw at bottom of housing For technical assistance call 1 800 4KENALL 1 800 453 6255 CUSTOMER SERVICE For warr...

Отзывы: