INSTRUCTION / INSTALLATION SHEET
Selective Call Intercom Door Unit
IS-0387 Rev. B
301Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
©Copyright 2011 by Legrand All Rights Reserved.
Page 1 of 3
1. Introduction
The Legrand Selective Call Intercom Door Unit, PN IC5002-XX (see
Figure
1
),
is a weather resistant door unit that allows a visitor to notify the occupants
of their presence by pushing the door chime button. The occupants can then
initiate two-way communications with the visitor and open the door (requires
separate door release device). The Door Unit is available in white (-WH),
shiny brass (-SB), antique brass (-AB), brushed stainless (-BS) and oil-
rubbed bronze (-OB).
2. Description
The Door Unit is a 2-gang product that mounts within an outdoor
weatherproof box (56” from the floor to the bottom of the box). There is
also a two-gang surface-mount box available (P/N IC5006-BK) for unique
or retrofit installation requirements.
3. Installation
Installation of the Selective Call Door Unit is best accomplished at multiple times during new construction, at
“Rough-in” before the drywall and siding is installed, and at “Trim-out” after the drywall is installed
.
A. “Rough-in” steps:
1. Run a Cat 5 cable from the Enclosure where the Selective Call Intercom Module will be installed to the
2 gang box at the Door Unit location.
NOTE: The maximum Cat 5 cable run distance between the SCI Module and another unit (Module,
Door, Patio or Room Unit) is 330’ with the following exception. One Door or Patio Unit may be placed
up to 1000’ (up to 650’ for a Video Door Unit) from the SCI Module, but it needs to be locally powered
and Legrand needs to be informed of and pre-approve this type of installation. If the Cat 5 run is
buried in an underground conduit, it should maintain a 16” separation from any 110VAC wiring.
Additional SCI Modules are recommended to be placed in the same enclosure, powered from the
same power strip, and interconnected with the shortest Cat 5 connections possible.
NOTE: It is important to keep all in-wall Category 5e cable runs at least 12 inches away from AC
electrical cables. If it proves necessary to cross an existing AC cable, do so only at a 90 degree angle.
B. “Trim-out”
steps:
NOTE: All terminations can be correctly completed by following the T568A pin assignments. It is
important that you accurately terminate using T568A at all locations. All terminations on the Selective Call
Intercom System utilize RJ45 jacks. Refer to
Figure 2
for correct T568A termination for RJ45 plugs.
RJ-45
Pin
1 – White/Green
2 – Green
3 – White Orange
4 – Blue
5 – White/Blue
6 – Orange
7 – White/Brown
8 – Brown
RJ-45
Pin
1 – White/Green
2 – Green
3 – White Orange
4 – Blue
5 – White/Blue
6 – Orange
7 – White/Brown
8 – Brown