![LEGRAND HPM EFTIL150SQWEKIT Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/legrand/hpm-eftil150sqwekit/hpm-eftil150sqwekit_instruction-manual_1871076004.webp)
Orientation of the junction box can be adjusted to suit the
fan engine’s
mounting location.
1. Unscrew and open the engine clamps.
2. Rotate the Engine to the desired position of the junction box.
3. Replace the engine clamps and tighten the screws.
Fig. 8
Engine
Clamps
Installation
6
Before commencing installation, remove all packaging from the product and ensure that power to the circuit has been isolated.
1. Choose a suitable mounting location for the inlet grille. Ensure there is adequate clearance from studs, pipes, wires etc (Fig. 9 ).
2. Cut a Ø160mm hole in the ceiling (Fig. 10).
3. Repeat steps 1 & 2 for the outlet grille.
4. Choose a suitable mounting location for the fan engine. Ensure that a power outlet is installed near the intended location of the engine.
5. Mount the engine to a suitable support using the mounting screws provided or other suitable fixings (not provided). The engine should be positioned
so that the power cord is pointing downwards.
6. Stretch, measure and cut the expandable duct to fit between each grille and the fan engine. To obtain optimum performance, the duct should be fully
stretched and without any holes or splits.
7. Attach duct to the outlet grille using the cable ties provided. Pass the duct through the outlet hole and mount the outlet grille to the ceiling / eave.
8. Slide the free end of the duct onto the outlet end of the fan engine and secure it with duct tape.
9. Attach duct to the inlet grille using the cable ties provided. Pass the duct through the inlet hole and mount the inlet grille to the ceiling.
10. Slide the free end of the duct onto the inlet end of the fan engine and secure it with duct tape.
11. Set the Speed Switch to the desired speed (O
–
Off, I
–
Low, II
–
High).
12. Plug the fan engine into the power outlet (Fig.11) or terminate wires as shown in Fig 12.
13. Switch on the inline fan and test function. Use a paper tissue held against the inlet grille to verify suction.
Fig. 9
Fig. 10
Fig. 11
Wiring
7
Fig. 13 Fan with Timer Module and Light fitting
Fig. 12
LS
Switched Active from wall
switch
L
Unswitched Active (
Only used
when timer module is fitted
)
N
Neutral
Cable clamp
Grommet
Bring mains wiring through cable grommet and terminate as
shown. Cable must be secured using cable clamp provided.
Active
L
N
Neutral
T
IM
E
R
LS