LEGRAND BTICINO MYHOME F411U2 Скачать руководство пользователя страница 2

2

23/03/2021

F411U2

ST-00000893-

If the device is installed in a MyHOME system it can be configured in two ways:
- PHYSICAL CONFIGURATION, inserting the configurators in position. The positions A|PL1 

and A|PL2 define the device's local addresses, while M defines the operating mode.

- Configuration via MyHOME_Suite software package, downloadable from the website 
  www.homesystems-legrandgroup.com; this mode has the advantage of offering many 

more options than the physical configuration.

  For a list of the procedures and their meanings, please refer to the instructions in this 

sheet and to the "Function Descriptions" help section in the MyHOME_Suite software 
package.

Note:

 For this device, the MyHOME Server automatically configures 2 channels.

Configuration

1.1 Addressing

Address type

Virtual configuration (MyHOME_Suite)

Physical configuration

Point-to-point

Room

0-10

A=1-9

Lighting point

0-15

PL1, PL2=1-9

Group

Group 1 - Group 10 = 0-255

G = 0-9

To use "Actuator as Slave with PUL function" and to adjust the "Delay OFF", the "Load 
type" (Actuator, Lamp, Valve, Differential reset, Fan, Irrigation, Controlled socket, Lock) 
use the MyHOME_Suite virtual configuration.

1. Light switch

NOTE 1):

 In the Master and Master PUL mode it is possible to set a 0-255 seconds OFF delay 

(through MyHOME_Suite) and 1-4 minutes delay through the physical configuration. With the OFF 
control the Master actuator is disabled; the Slave actuator is disabled after the time set with the 
configurators has elapsed. The configurator value indicated in the table defines the timeout, after 
which the actuator switches off its Slave.  
This mode is operative only if PL1≠PL2

NOTE 2):

 In blinds configuration, it can only be 0

NOTE 3):

 For configurations C=0 (or virtual “Zero crossing”), the LED flashes if L and N are not 

connected. With C=1 and neutral not connected relay can be used simply as a clean contact.

1.2 Mode

Virtual configuration (MyHOME_Suite)

Physical configuration

Function

Parameter / setting

Master Actuator

Master

M=0

Actuator as Slave. Receives a control sent by a Master actuator 
which has the same address

Slave

M=SLA

Button (On monostable) ignores Room and General controls

Master PUL

M=PUL

Delay OFF: Master actuator with OFF control delayed on the  
corresponding Slave actuator. 

1)  2)

0 - 255

No configurator

0 sec.

M=1

1 minute

M=2

2 minutes

M=3

3 minutes

M=4

4 minutes

Load control mode 

3)

C=0

with zero crossing

C=1

without zero crossing

2 Relay actuator 10A

EN