F411U2
ST-00000893-
If the device is installed in a MyHOME system it can be configured in two ways:
- PHYSICAL CONFIGURATION, inserting the configurators in position. The positions A|PL1
and A|PL2 define the device's local addresses, while M defines the operating mode.
- Configuration via MyHOME_Suite software package, downloadable from the website
www.homesystems-legrandgroup.com; this mode has the advantage of offering many
more options than the physical configuration.
For a list of the procedures and their meanings, please refer to the instructions in this
sheet and to the "Function Descriptions" help section in the MyHOME_Suite software
package.
Note:
For this device, the MyHOME Server automatically configures 2 channels.
Configuration
1.1 Addressing
Address type
Virtual configuration (MyHOME_Suite)
Physical configuration
Point-to-point
Room
0-10
A=1-9
Lighting point
0-15
PL1, PL2=1-9
Group
Group 1 - Group 10 = 0-255
G = 0-9
To use "Actuator as Slave with PUL function" and to adjust the "Delay OFF", the "Load
type" (Actuator, Lamp, Valve, Differential reset, Fan, Irrigation, Controlled socket, Lock)
use the MyHOME_Suite virtual configuration.
1. Light switch
NOTE 1):
In the Master and Master PUL mode it is possible to set a 0-255 seconds OFF delay
(through MyHOME_Suite) and 1-4 minutes delay through the physical configuration. With the OFF
control the Master actuator is disabled; the Slave actuator is disabled after the time set with the
configurators has elapsed. The configurator value indicated in the table defines the timeout, after
which the actuator switches off its Slave.
This mode is operative only if PL1≠PL2
NOTE 2):
In blinds configuration, it can only be 0
NOTE 3):
For configurations C=0 (or virtual “Zero crossing”), the LED flashes if L and N are not
connected. With C=1 and neutral not connected relay can be used simply as a clean contact.
1.2 Mode
Virtual configuration (MyHOME_Suite)
Physical configuration
Function
Parameter / setting
Master Actuator
Master
M=0
Actuator as Slave. Receives a control sent by a Master actuator
which has the same address
Slave
M=SLA
Button (On monostable) ignores Room and General controls
Master PUL
M=PUL
Delay OFF: Master actuator with OFF control delayed on the
corresponding Slave actuator.
1) 2)
0 - 255
No configurator
0 sec.
M=1
1 minute
M=2
2 minutes
M=3
3 minutes
M=4
4 minutes
Load control mode
3)
C=0
with zero crossing
C=1
without zero crossing
2 Relay actuator 10A
EN