The supported OCPP 1.6J functions (Borne to Server) are as follows :
• “Authorize“ ex :
[2,“26765260829432299233“,“Authorize“,{“idTag“:“XXXXXXXXXXXXXXXX“}]
IdTagInfo support expiryDate and parentIdTag.
• “BootNotification” ex : [2,“46740660243372615052“,“BootNotification“,{“chargeBoxSerialNum-
ber“:“260988“,“chargePointModel“:“059004“,“chargePointVendor“:“Legrand“,“firmwareVersion“:“V01.01.65/
V01.01.08“,“meterType“:“internal“}]
• “DataTransfert” : N.A
• “DiagnosticsStatusNotification” example coming soon
• “FirmwareStatusNotification” example coming soon
• “Heartbeat” ex :
[2,“11101862315294265356“,“Heartbeat“,{}]
• “MeterValues” ex :
[2,“14057949118014675557“,“MeterValues“,{“connectorId“:2,“transactionId“:XXXX,“meterValue“:[{“-
timestamp“:“2019-04-19T16:26:44.277+02:00“,“sampledValue“:[{“value“:“1.64“,“context“:“Sample.
C l o c k “,“ f o r m a t“ : “ R a w “,“ m e s u r a n d “ : “ C u r re n t . I m p o r t“,“ l o c a t i o n “ : “ O u t l e t“,“ u n i t“ : “A“ } , { “ v a -
lue“:“3.1816661“,“context“:“Sample.Clock“,“format“:“Raw“,“mesurand“:“Energy.Active.Import.
Interval“,“unit“:“Wh“},{“value“:“381.79993“,“context“:“Sample.Clock“,“format“:“Raw“,“mesurand“:“Power.Active.
Export“,“location“:“Outlet“,“unit“:“W“}]}]}]
• “StartTransaction” ex :
[2,“31895085733530537308“,“StartTransaction“,{“connectorId“:2,“idTag“:“XXXXXXX“,“meterStart“:0,“reservatio-
nId“:0,“timestamp“:“2019-04-19T16:25:43.083+02:00“}]
IdTagInfo support expiryDate and parentIdTag.