Technical data sheet: F01163EN/01  

Updated: 30/03/2015  

             Created: 07/07/2010

Catalogue number(s): 0 882 30

Configuration tool with screen

2

 Select the application 

Alert window warning that some data may be lost. Select Continue to 

start updating. 

3

 Eg: Lighting management 

Updating is complete.

4

 Connect the configuration tool to the PC

Once connected, the configuration tool should switch on. If not, 

disconnect and then reconnect it to the USB cable.

5

 Choose whether or not to start updating 

4. UPDATING (CONTINUED)

4. UPDATING (CONTINUED)

Important: The configuration tool must be switched off

Note:  All technical information is available on

Commercial premises - office buildings:

Passage areas and corridors: 100 lux 

Stairs: 150 lux

Canteens: 200 lux

First-aid room: 500 lux

Warehouse: 100 lux

Offices: 300 - 500 lux 

Conference rooms: 500 lux 

Reception rooms: 300 lux 

Technical drawing: 750 lux 
Manufacturing areas:

Packaging rooms: 300 lux 

Visual work during manufacturing: 1000 lux 

Assembly line: 1500 lux 
Warehouses:

Sales areas: 300 lux 

Checkout areas: 500 lux
Other examples:

Moonlit night: 0.5 lux

Well-lit street at night: 20 - 70 lux

Living premises: 100 - 200 lux

Well-lit apartment: 200 - 400 lux

Work premises: 200 - 3000 lux

Stadium at night: 1500 lux

Outside with cloudy sky: 25,000 lux

Outside in full sunshine: 50,000 to 100,000 lux

5. STANDARD EN12464-1 RECOMMENDATIONS

Содержание 0 882 30

Страница 1: ...he product to be measured At a maximum angle of 15 in the axis of the IR transmission and reception LED see figure 4 m 4 m 15 15 Backlit screen automatic switch off Weight 71 g Impact resistance IK04 Operating temperature 5 C to 45 C Storage temperature 20 C to 70 C Recharging Use a mini USB cable not supplied to recharge the configuration tool via a standard USB socket Note Updating software is a...

Страница 2: ... 2 3 s 1 2 3 5 4 6 Sensor parameter Advanced mode Files Sensor PnL Sensor parameters 1 1 2 3 Time delay 000 H 15 Min 00 Sec Max time delay 255 H 59 Min 59 Sec A Daylight setpoint 0500 lux Max 1275 lux C Sensitivity Very high US High HF High PIR Very high High Medium Low B Detection scheme E IR and US Maintain IR or US Retrigger IR or US Initial IR and US IR or US HF only PIR and HF PIR or HF IR on...

Страница 3: ...oint Value at which the load switches on if the light level is less than the setting and goes off if it is above this setpoint The daylight setpoint can be set up to a maximum of 1275 lux D Mode There are 4 different operating modes Auto on Auto off mode Comes on automatically On detection of a presence if there is insufficient natural light Turns off automatically If no presence is detected and a...

Страница 4: ...ode Files Sensor PnL Files 3 Files File name 3 NAVIGATION CONTINUED 3 NAVIGATION CONTINUED The Files menu can be used to display the customised settings saved Up to 26 files can be saved xx H xx MIN xx Sec PIR High US Low Closed loop xxx Lux x Lux Light regulation Mode Detection scheme Detection scheme Detection scheme Alert Time delay Sensitivity Sensitivity Loop type Daylight setpoint Provision ...

Страница 5: ...uct documentation is displayed 5 Install the updating file 6 Click on Yes 8 Select the desired language then click OK 7 Click on Yes 9 Click on Next 3 Click on the icon to access software downloading 4 Download the file 3 2 7 Settings 4 1 Installing the software Files Sensor PnL Test Tool config Settings 6 Languages Version Battery A C B Version Firmware X X XX B Languages Français English Italian...

Страница 6: ...lete 16 Click on Finish 1 Launch the application shortcut on the Desktop 15 Select Install this driver software anyway 11 Click on Browse to indicate the destination directory 12 Click on Next 13 To create a software icon on your desktop check the corresponding box then click on Next This window summarises the tasks selected earlier 14 Click on Install to confirm these actions or else on Previous ...

Страница 7: ...st be switched off Note All technical information is available on Commercial premises office buildings Passage areas and corridors 100 lux Stairs 150 lux Canteens 200 lux First aid room 500 lux Warehouse 100 lux Offices 300 500 lux Conference rooms 500 lux Reception rooms 300 lux Technical drawing 750 lux Manufacturing areas Packaging rooms 300 lux Visual work during manufacturing 1000 lux Assembl...

Страница 8: ...lowing products Hexane En 60669 1 Methylated spirit Soapy water Diluted ammonia Bleach diluted to 10 Window cleaning products WARNING Always test before using other special cleaning products Directive CE Product standard EN 60 669 2 1 Environmental standards European Directive 2002 96 EC WEEE Waste Electrical and Electronic Equipment European Directive 2002 95 EC RoHS Restriction of Hazardous Subs...

Отзывы: