1.
2.
3.
4.
5.
6.
7.
8.
Montage Torflügel und Anschlussgitter
Mögliche Toraufhängungen
8.
VP
7.
6.
2.
4.
5.
2.
3.
1.
Where the fence runs on the outside of
the property, the gate wings should
preferably open inwards. DIN left or
DIN right opening is determined by the
position of the gatepost (VP) to which
the gate wing is fixed.
Opening Directions
1
BTF + 60 mm
BTF + 100 mm
BTF
30
VP
30
LEGI-Revolving Wing Gate
VARIO-M
Assembly Instructions
patented
www.legi.de
DIN left opening
Internal
DIN right opening
Internal
The axial dimension of the gateposts to
be concreted is the result of the desired
gate wing width (BTF) plus 100 mm
Concreting Dimension
Assembled gatepost VP.
Screw the hinge sleeves to the gate wing.
The hinge sleeves can be found on the
side towards which the gate wing opens.
Fix the lower screw bracket to the gatepost
and hang the lower hinge sleeve in the
screw bracket.
Hang the screw bracket in the upper
hinge sleeve then screw the screw
bracket to the gatepost.
After aligning of the gate wing, assemble
the connecting gratings. These must be
trimmed to size and the cut section must
be properly kept.
Exception: Cf. Lock Case Assembly
Hang the clamping tubes.
Put on the post cap with counter plate
and screw it to the post.
Assembled gate wing.
Cap
Counter plate
Grating
Clamping tube
Fully assembled
M10 washer
M10 screw
Hinge sleeve
Screw bracket
We reserve the right to make structural modifications.