![Legend DV36 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/legend/dv36/dv36_owners-manual_1868856019.webp)
19
Step 4. Positioning, Leveling, and
Securing the Fireplace
The diagram below shows how to properly position, level,
and secure the fireplace.
• Place the fireplace into position.
• Level the fireplace from side to side and from front to back.
• Secure the fireplace to the framing by nailing or screwing.
Step 5. The Gas Control System
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
DV36-NG System Date
For 0 to 4500 feet altitude
Injector Size: 2.45mm (#41 DMS)
Nominal Gas Consumption (Max): 27.4 MJ/h
Nominal Gas Consumption (Min): 14.6 MJ/h
Inlet Gas Pressure: 1.13 kPa
Test Point Pressure @ Max Rate: 0.87 kPa*
*Reference test point pressure is measured at the
outlet of the combination control body.
Содержание DV36
Страница 18: ...18 ...
Страница 25: ...25 Positioning the Logs ...
Страница 30: ...30 THE LIGHTING PLATE INSTRUCTIONS ...