www.LEGALETT.com
Operating voltage ...............................1 P - 230V 60Hz
Fan motor power consumption ............................225W
Breaker rating (GFI required) ................................. 30A
Output, electrical.......................................... 4 x 1250W
Air flow with:
8 - 100 mm (4") pipes.................
≥
900 m
3
/h / 530 CFM
Air flow with:
20 - 50 mm (2") pipes.................
≥
750 m
3
/h / 440 CFM
TECHNICAL DATA
FUNCTION
1 P - 230V 60Hz
Thermostat 1-4
30A Circuit Breaker
The 4000E-24 heating-unit is installed in the foundation
slab or suspended floor, and contains a fan and
four heating elements, with contactors that are
controlled by 1 - 4 external electric room thermostats.
This data is generic.
Each Legalett installation is unique. Refer to customized
specifications on your installation design drawing for
actual design parameters.
The 4000E-24 is controlled by one (single zone) to four
(quad zone) external electric room thermostats. These
external thermostats operate the contactors in the unit,
energizing the heating coil and fan when the room needs
heat. The unit is also equipped with seven overheating
protection devices.
When controlled by a programmable thermostat, the
4000E-24 can benefit from two-tiered energy rates for
night storage of less expensive energy in the LEGALETT
heated floor.
It is used together with heating unit box 4000A 100/100
(4"/100 mm spiral pipes) or with heating unit box
4000A 50/50 (2"/50 mm plastic pipes).
June, 2007
Revised:June, 2008
Form № 0535
Page 1 of 2
HEATING UNIT - 4000E-24
25