LEGACY SPA - DIAGNOSTIC MESSAGES
Enterprise SE & Inspire SE
3
aCtIOn rEQuIrED
The control panel will be disabled until
power returns. Spa settings will be
preserved until next power up.
After the pump has been running
for 2 minutes, the temperature will
be displayed.
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. Once
the heater has cooled, reset by pushing
any button. If spa does not reset, shut
off the power to the spa and call your
dealer or service organization.
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. At
107°F/42°C, the spa should automatically
reset. If spa does not reset, shut off the
power to the spa and call your dealer
or service organization.
No action required. The pump(s) will
automatically activate regardless of
spa status.
If the problem persists, contact your
dealer or service organization. (May
appear temporarily in an overheat
situation and disappear when the
heater cools.)
If the problem persists, contact your
dealer or service organization. (May
appear temporarily in an overheat
situation and disappear when the
heater cools.)
MEanInG
No message on display.
Power has been cut off
to the spa.
Temperature
unknown.
“Overheat” - The spa
has shut down. One
of the sensors has
detected 118°F/48°C at
the heater.
“Overheat” - The spa
has shut down. One of
the sensors has detected
that the spa water is
110°F/43°C.
“Ice” - Potential freeze
condition detected.
Spa is shut down. The
sensor that is plugged
into the Sensor “A”
jack is not working.
Spa is shut down. The
sensor that is plugged
into the Sensor “B”
jack is not working.
MESSaGE
LEGACY SPA - DIAGNOSTIC MESSAGES
Enterprise SE & Inspire SE
4
aCtIOn rEQuIrED
If the problem persists, contact your
dealer or service organization.
Check water level in spa. Refill if
necessary. If the water level is okay,
make sure the pumps have been primed.
If problem persists, contact your dealer
or service organization.
Follow action required for “
”
message. Heating capability of the spa
will not reset automatically; you may
press any button to reset.
Check water level in spa. Refill if
necessary. If water level is okay, make
sure the pump(s) have been primed.
Press any button to reset, or this message
will automatically reset within 15 minutes.
If problem persists, contact your dealer
or service organization.
Follow action required for “
”
message. Spa will not automatically
reset. Press any button to reset.
MEanInG
Sensors are out of
balance. If alternating
with spa temperature,
it may just be a
temporary condition.
If flashing by itself,
spa is shut down.
A significant difference
between tempera-
ture sensors has been
detected. This could
indicate a flow
problem.
Persistent low flow
problems. (Displays on
the fifth occurrence of
“
” message within
24 hours.) Heater is
shut down, but other
spa functions continue
to run normally.
Possible inadequate
water, poor flow, or air
bubbles in detected in
the heater. Spa is shut
down for 15 minutes.
Inadequate water
detected in heater.
(Displays on third
occurrence of “
”
message.) Spa is
shut down.
MESSaGE
Warning! Shock Hazard! no user Serviceable parts. Do not attempt service of this
control system. Contact your dealer or service organization for assistance. Follow all
owner’s manual power connection instructions. Installation must be performed by
a licensed electrician and all grounding connections must be properly installed.