Safety Tips, Care and Maintenance

Safety Tips

If you are soldering during faucet installation,remove cartridges, seats, gaskets and washers prior to 
applying flame, otherwise you will void the warranty.

Cover drain openings to avoid losing small parts.

When cutting or soldering pipe, use safety glasses to protect your eyes.

Important Points

Prior to beginning installation. turn off the cold and hot water lines and open the old faucet to release
built-up pressure.

Overtightening nuts may cause damage.

Wrap all threaded connections with pipe tape available at your local plumbing supply store.
Always wrap in a clockwise direction. The fittings should be installed by a state-licenced plumber.

Please note:
When there is a difference in water pressure between hot and cold supplies to the mixing valve, the 
pressures should be equalized by a plumber in accordance with best practice and legislation.

Maintenance

Your new bathroom faucet is designed for years of trouble-free performance. Keep it looking new by 
cleaning it periodically with a soft cloth. Avoid abrasive cleaners, wire wool and harsh chemicals as 
these will dull the finish and void your warranty.

Routine Maintenance

The frequency and extent of attention required will vary according to prevailing site and operational 
conditions, however a 12 monthly maintenance schedule is recommended.

If the product has operated satisfactorily for some time, but performance has been degraded, please 
check the Fault Finder section to identify the problem.

Maintenance Check List

 s 7ORNORDAMAGEDSEALSANDWASHERS
 s $AMAGEDSEALFACES
 s 4HREADWEAR
 s )NCORRECTADJUSTMENT
 s #OMPONENTFAILURE
 s $EBRISORLIMESCALEBUILDUP

Содержание R1-4033

Страница 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS R1 4033 DECK FLOW CONTROL ROUGHS 1 PAIR TO SUIT K1 1026 M1 1026 X1 1026 CW 1026 CB 1026...

Страница 2: ...2 Contents Dimensions 3 Installation Procedure 4 Parts List 6 Fault Finder 7 Safety Tips Care and Maintenance 8 Guarantee 9...

Страница 3: ...4 223mm 8 12 203 2mm 304 8mm 1 2 5 3 8 12mm 136mm 1 2 14NPSM 2B 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without no...

Страница 4: ...t plumbing products be installed by a licensed professional Shut off main water supply before installation 1 Remove the protective bubble bag cap and top mounting nut from body assembly 2 Install the...

Страница 5: ...ies relying on speci c gauge A B D supplied as the gure indicated to make sure they can t with the trim in various ranges After that tighten xing nuts from below by wrench Gauge A 027105 for M1 1025 M...

Страница 6: ...22 5 Nut 054026 6 Body 061113H 50 7 Body 061113C 50 8 Cartridge 507724 50 9 Rubber protective cap 038103 10 Gauge A for Fleetwood M2 series 027105 11 Gauge B for Kafka K1 XO X1 series 027104 12 Gauge...

Страница 7: ...7 Fault Finder Fault Cause Recti cation Leaks around handle Cartridge has come loose or damaged Tighten reinstall the cartridge or replacement the cartridge if it is damaged...