background image

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

M2-4404

Содержание M2-4404

Страница 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M2 4404 ...

Страница 2: ...2 Contents Dimensions 3 InstalLation Procedure 4 Parts List 7 Fault Finder 8 Safety Tips Care and Maintenance 9 Guarantee 10 ...

Страница 3: ...0 m m Ø3 Ø76mm Ø1 1 4 Ø31 7mm 2 11 16 68m m 2 3 4 3 3 8 70mm 86mm W3 16 24 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without notice as part of the company s product development process ...

Страница 4: ...l Shut off main water supply before installation 1 Before installing the valve into the wall please note that a distance between 80mm 105mm from the wall surface to the rear of the valve should be left so that the trim can be fitted correctly 2 Install valve assembly into the wall 3 Cut a hole in the wall surface for fitting the trim kit The hole dimension is as shown in figure 3 4 Throw away the pro...

Страница 5: ...n on the flow controller Turn the thermostatic cartridge until the water temperature is at 38 Suggestion attach a hose to the outlets and guide the water to the basin or another container to test the temperature and prevent it from spilling on the floor 7 Turn off the water supply Install the stopper and make sure its B plane as shown is horizontal and on the left side 8 Fix the stem extension and t...

Страница 6: ... be installed by a licensed professional Shut off main water supply before installation 9 Install the canopies 10 Fix the front plate with screws 11 Fix the canopy with screw When it is fixed check that the temperature limitbutton is in the horizontal position 12 Install handle assembly with set screws ...

Страница 7: ...le 029685 51 10 Screw 008994 11 Button 036272 12 Spring 005157 13 Adaptor 067960 14 Pin 003147 15 Canopy 018959 52 16 Set screw 065086 17 Adjusting ring 104295 18 Screw 008186 19 Allen wrench 031000 20 Allen wrench 031003 21 Screw 008196 22 Spindle 110386 6 15 2 13 1 18 17 16 9 11 12 14 10 4 19 20 7 8 21 22 5 3 7 Parts List Exploded view ...

Страница 8: ...Fault Finder Fault Cause Rectification Wobbling of handle The fixing screw comes loose Check for fixing screw and re tighten it properly Wobbling of canopy The canopy comes loose Check and tighten the canopy ...

Страница 9: ... water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom faucet is designed for years of trouble free performance Keep it looking new by cleaning it periodically with a soft cloth Avoid abrasive cleaners wire wool and harsh chemicals as these will dull the finish an...

Страница 10: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period s The guarantee is valid in private homes for 5 years from the purchase date Proof of purchase has to be provided when making a guarantee claim s By use in commercial or institutional applications the gua...

Страница 11: ...ts are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti Copying in Design LEFROY BROOKS INC 1828 TROUTMAN STREET RIDGEWOOD NY 11385 TELEPHONE 718 302 5292 FAX 718 302 4177 COPYRIGHT LBIP LTD 2014 718 302 5292 www lefroybrooks com ...