Lefroy Brooks M1-4404 Скачать руководство пользователя страница 7

 19 

 5 

 6 

 2 

 16 

 15 

 10 

 1 

 18 

 17 

 8 

 9 

 13 

 11 

 3 

 22 

 23 

 4 

 14 

 20 

 21 

 12 

 7 

Screw (008186)

Spindle (110388)

Clip (012242)

Screw (008189)

Canopy (018960)

Handle (029686)

Set screw (292598)

Button (036272)

Spring (005157)

10  Handle (029685)
11  Screw (008994)
12  Adaptor (067960-50)
13  Pin (003147)
14  Screw (008196)
15  Canopy (018959-50)
16  Spindle (110386)

17  Set screw (065086)
18  Adjusting ring (104295) 
19  Front plate (006582-51)
20  Seal (010939)
21  Seal (013817)
22  Allen key (031003) 
23  Allen key (031000)

7

Parts List

Exploded view

Содержание M1-4404

Страница 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M1 4404 CROSS HANDLE THERMOSTATIC WITH LEVER FLOW CONTROL 2 WAY DIVERTER TRIM ONLY TO SUIT M1 4203 ROUGH...

Страница 2: ...2 Contents Dimensions 3 Instalation Procedure 4 Parts List 7 Fault Finder 8 Safety Tips Care and Maintenance 9 Guarantee 10...

Страница 3: ...76mm 1 1 4 31 7mm 1 9 16 2 15 16 40 75mm 9 1 16 230mm 5 7 8 150mm 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without...

Страница 4: ...ut off main water supply before installation 1 Before installing the valve into the wall please note that a distance between 80mm 105mm from the wall surface to the rear of the valve should be left so...

Страница 5: ...on the flow controller Turn the thermostatic cartridge until the water temperature is at 38 Suggestion attach a hose to the outlets and guide the water to the basin or another container to test the te...

Страница 6: ...products be installed by a licensed professional Shut off main water supply before installation 9 Install the canopies 10 Fix the front plate with screws 11 Fix the canopy with screw When it is fixed...

Страница 7: ...029686 7 Set screw 292598 8 Button 036272 9 Spring 005157 10 Handle 029685 11 Screw 008994 12 Adaptor 067960 50 13 Pin 003147 14 Screw 008196 15 Canopy 018959 50 16 Spindle 110386 17 Set screw 065086...

Страница 8: ...lt Finder Fault Cause Rectification Wobbling of handle The fixing screw comes loose Check for fixing screw and re tighten it properly Wobbling of canopy The canopy comes loose Check and tighten the ca...

Страница 9: ...in water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom fauce...

Страница 10: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period The...

Страница 11: ...s are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti...

Отзывы: