6
7
8
9
10
Dimple on
valve stem
Notch
Stopper A
(marked #049000)
Stopper B
(marked #049001)
0 tooth
8 teeth
12 teeth
HIGHT TEMPERATURE SETTING
(with 150° operation range)
AVERAGE TEMPERATURE SETTING
(with 90° operation range)
LOW TEMPERATURE SETTING
(with 60° operation range)
Stopper B
(marked
#049001)
Stopper A
(marked
#049000)
6
Installation Procedure
Steps 6-10
Lefroy Brooks always recommends that plumbing products be installed by a licensed professional.
Shut off main water supply before installation.
6
Turn the valve stem so that the round dimple on the stem is facing upwards.
7
Install stopper A onto valve stem. Notch on stopper A should point upward.
8
Install stopper B. The word “up” should face out.
9
Figures I, II, III show how to adjust the temperature limit stop. Having this open at eight notches is
recommended.
10
Install washer.