background image

6

7

8

9

10

Dimple on

valve stem

Notch

Stopper A

(marked #049000)

Stopper B

(marked #049001)

0 tooth

8 teeth

12 teeth

 HIGHT TEMPERATURE SETTING

     (with 150° operation range) 

AVERAGE TEMPERATURE SETTING

     (with 90° operation range)

LOW TEMPERATURE SETTING

     (with 60° operation range)

Stopper B
(marked 
#049001)

Stopper A
(marked 
#049000)

6

Installation Procedure

Steps 6-10

Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. 
Shut off main water supply before installation.

6

 

Turn the valve stem so that the round dimple on the stem is facing upwards.

7

 

Install stopper A onto valve stem. Notch on stopper A should point upward.

8

 

Install stopper B. The word “up” should face out.

9

 

Figures I, II, III show how to adjust the temperature limit stop. Having this open at eight notches is  

 recommended.

10

 

Install washer.

Содержание M1-4100

Страница 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M1 4100 SINGLE HANDLE PRESSURE BALANCE ROUGH TO SUIT M1 4300 M1 4301...

Страница 2: ...2 Contents Dimensions 3 Instalation Procedure 4 Parts List 7 Fault Finder 8 Safety Tips Care and Maintenance 9 Guarantee 10...

Страница 3: ...0mm 1 2 14NPT 5 3 16 134mm 1 2 14NPT 1 2 14NPT 2 7 16 62mm 2 15 16 75mm 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change wi...

Страница 4: ...Keep a distance of 7mm at least from the wall surface to the front of the plaster guard so that the trim kit CW 4070 CB 4070 can be fitted successfully 4 Steps 1 2 Installation Procedure Lefroy Brooks...

Страница 5: ...products be installed by a licensed professional Shut off main water supply before installation 3 Cut a hole on the wall surface for fitting the trim kit The hole dimension is as shown in figure 3 4 T...

Страница 6: ...6 Installation Procedure Steps 6 10 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 6 Turn the valve stem...

Страница 7: ...12 2 Adjusting ring 104105 3 Screw 075083 4 Fixing board 126055 5 Nut 009808 6 Sleeve 041061 7 PB cartridge assembly 507150 8 Check valve 507037 9 Spring 005006 10 Body 061930 11 Screw 008241 12 Washe...

Страница 8: ...old is too low Inspect check valves to ensure they are fully open flush the system Remove and clean showerheads May need to replace if clogged Check for water pressure and adjust to proper pressure le...

Страница 9: ...in water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom fauce...

Страница 10: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period The...

Страница 11: ...s are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti...

Отзывы: