Lefroy Brooks CW-4711 Скачать руководство пользователя страница 4

1

2

Cold

Hot

4

Steps 1-2

Installation Procedure

Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. 
Shut off main water supply before installation.

1

 

Install the Hot-side-body in the left hole and the Cold-side-body in the right hole.

2

 

Install Hot and Cold handle assemblies.

Содержание CW-4711

Страница 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS CW 4711 WL 1560 WHITE LEVER TUBULAR 3 HOLE KITCHEN MIXER...

Страница 2: ...2 Contents Dimensions 3 InstalLation Procedure 4 Parts List 6 Fault Finder 7 Safety Tips Care and Maintenance 8 Guarantee 9...

Страница 3: ...mm 12 1 4 311 9mm 2 9 1 6 2 4 U N E F 2 A 2 3 16 55mm 2 3 16 55mm 6 12 152 4 305mm 3 5 16 84mm 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions a...

Страница 4: ...oks always recommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 1 Install the Hot side body in the left hole and the Cold side body...

Страница 5: ...allation Procedure Steps 3 4 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 3 Fix the spout 4 Install the...

Страница 6: ...ommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 5 Install the hose 6 Take off aerator 7 Turn on water supply and handle to clear a...

Страница 7: ...4026N 19 Connector 015004W 20 Ceramic cap C 129313C 21 Adaptor 205144 22 Handle sleeve 108924 23 Handle stem 017094 24 Handle end cap 109376 25 O ring 048085 26 Canopy 018220 27 Washer 013224 28 Clip...

Страница 8: ...sket placement Leaks around handle Cartridge has come loose or damaged Tighten reinstall the cartridge or replacement the cartridge if it is damaged Aerator leaks or has an inconsistent water ow patte...

Страница 9: ...ater pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom faucet is...

Страница 10: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period s Th...

Страница 11: ...s are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti...

Отзывы: