MPC2810 Motion Controller Hardware Manual
39
Fig. 4-4 Test PtoP Motion
(3). Test IO Module
Clicking the button
is to enter IO Test Module.
Standard Inputs and Specific Inputs status will be shown as Fig. 4-5. Red
presents active-high. Green presents active-low. Blue presents error..
The Specific Inputs function will be enabled with the
“
check
”
symbol, which
is behind the signal shown as Fig. 4-5. Without
“
check
”
symbol, it is the
Standard Inputs.
“
Negative Logic
”
and
“
Positive Logic
”
is for setting active-level in the
Specific Inputs.
24-channel Universal Outputs are on the bottom of window. Initially, they are
red, which means OFF. After clicking the button, the Red will be switched to the
Green. It means ON, which connects to the GND of inputted 24V.