background image

 

 

lubrication. If the door moves part way from the 
two-finger location but stops short of the cabinet, 
the compression of the gasket along the hinge side 
of the door should be checked. If there is too much 
compression, the door will bind when closed and 
should have its hinge-mount location checked and 
possibly adjusted. Removing the hinge covers will 
expose the spring-loads for tension adjustment or 
removal. Removal of the spring-load will expose 
the hinge-adjustment plate and mounting screws 
should hinge adjustment be required. See 

Figure 2

 

for instruction regarding spring-load installation and 
adjustment. 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SPRING CARTRIDGE INSTALLATION INSTRUCTIONS

 

 

 

 

  Figure 1 

 

 

 

 

 Figure 2 

 

 

 

 

 

Figure 3 

 

1) Install No. 220 Hinge with Adjustment Plate. 

 

2)  Assemble Spring Cartridge.  Grease bushing end of pin prior to insertion into Stationary Bushing.  Apply a 

small amount of grease to the hinge-pin hole on the end of the Adjustment Collar Assembly.  (Fig. 1). 

 

3) Place Thrust Washer and Stationary Bushing over square pin in the Hinge and insert the Adjustment Pin into 

the Adjustment Collar. Using the Adjustment Pin, compress the Spring and place the Adjustment Collar over 

the round pin (Fig. 2). 

 

Содержание REACH-IN STORAGE Series

Страница 1: ...950 1 800 766 5337 www leerinc com STORAGE FREEZER INSTALLATION OPERATION AND SERVICE MANUAL WARNING This product can expose you to chemicals including nickel which is known to the State of California...

Страница 2: ...de Display 4 Electronic Control Operation 5 Auto Defrost Control 5 Possible Displayed Alarm Codes 5 Loading Product 5 Condenser Fan Pressure Switch 6 Maintenance 6 Cleaning the Freezer 6 Cleaning Door...

Страница 3: ...ls is available Contact the Merchandiser Sales Department at Leer Inc for additional information Electrical Warning Component parts shall only be replaced with like components Electrical and servicing...

Страница 4: ...ack surface of the condensate evaporator housing and any wall surface behind the cabinet which allows for heat dissipation away from the surface of the wall The main power cord should also be routed t...

Страница 5: ...e Possible Displayed Alarm Codes P1 Air Probe failure The control will override the P1 functions and cycle the compressor for 17 minutes until the probe fault can be corrected P2 Evaporator Probe fail...

Страница 6: ...like material that can be cleaned using most kitchen and bath cleaners designed for mildew removal Review manufacturer information and instructions on any cleaning agent prior to use to determine the...

Страница 7: ...d immediately switch power from the defrost mode to the run mode If temperature is not reached at probe P2 the defrost cycle will continue for the entire 24 minute programmed cycle prior to returning...

Страница 8: ...unting screws should hinge adjustment be required See Figure 2 for instruction regarding spring load installation and adjustment SPRING CARTRIDGE INSTALLATION INSTRUCTIONS Figure 1 Figure 2 Figure 3 1...

Страница 9: ...ng tension Figure 2 Spring Install Instructions Solid Door Magnetic Gasket Replacement Instructions 1 Position solid door on a flat non abrasive surface exterior side down 2 Remove old gasket by grasp...

Страница 10: ...10 Step 5 Figure 3 Door Gasket Install...

Страница 11: ...11 Electronic Control AD Wiring Diagram W Relay...