8
lubrication. If the door moves part way from the
two-finger location but stops short of the cabinet,
the compression of the gasket along the hinge side
of the door should be checked. If there is too much
compression, the door will bind when closed and
should have its hinge-mount location checked and
possibly adjusted. Removing the hinge covers will
expose the spring-loads for tension adjustment or
removal. Removal of the spring-load will expose
the hinge-adjustment plate and mounting screws
should hinge adjustment be required. See
Figure 2
for instruction regarding spring-load installation and
adjustment.
SPRING CARTRIDGE INSTALLATION INSTRUCTIONS
Figure 1
Figure 2
Figure 3
1) Install No. 220 Hinge with Adjustment Plate.
2) Assemble Spring Cartridge. Grease bushing end of pin prior to insertion into Stationary Bushing. Apply a
small amount of grease to the hinge-pin hole on the end of the Adjustment Collar Assembly. (Fig. 1).
3) Place Thrust Washer and Stationary Bushing over square pin in the Hinge and insert the Adjustment Pin into
the Adjustment Collar. Using the Adjustment Pin, compress the Spring and place the Adjustment Collar over
the round pin (Fig. 2).