9
Installer Icon Type
0x0C07
(ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY)
User Icon Type
0x0C07
(ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY)
Association Command Class
Motion Sensor supports 2 association groups and max 5 nodes for each group.
Association Group Info Command Class
Association Group Info
Grouping identifier
Group Name
Profile MS
Profile LS
01
Lifeline
0x00
0x01
02
On/Off control
0x71
0x07
Association Group Command List
Group 1
Command List Support
Command Class
COMMAND_CLASS_NOTIFICATION(0x71)
Command
NOTIFICATION_REPORT(0x05)
Command Class
COMMAND_CLASS_BATTERY(0x80)
Command
BATTERY_REPORT(0x03)
Command Class
COMMAND_CLASS_DEVICE_RESET_LOCALLY(0x5A)
Command
DEVICE_RESET_LOCALLY_NOTIFICATION(0x01)
Command Class
COMMAND_CLASS_SENSOR_MULTILEVEL(0x31)
Command
SENSOR_MULTILEVEL_REPORT(0x05)
Group 2
Command List Support
Command Class
COMMAND_CLASS_BASIC(0x20)
Command
BASIC_SET(0x01)
Notification Commands
Notification Type
Notification Event
HOME_SECURITY (0x07)
(0x00) NO_EVENT
(0x03) TAMPERING_COVERING_REMOVED
(0x08) MOTION_DETECTION_UNKNOWN_LOCATION
POWER_MANAGEMENT (0x08)
(0x0A) REPLACE_BATTERY_SOON
(0x0B) REPLACE_BATTERY_NOW
(0x00) NO_EVENT