![Lee Precision LOAD-MASTER Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/lee-precision/load-master/load-master_complete-instructions_1867888007.webp)
7
Remove
powder
or debris
from
shelf
Problem
Possible Cause
Remedy
Primers not fully seated
Lever not lowered to full down sto
p
Actuate lever to FULL DOWN position
Die set too deeply to press
Adjust dies to insure carrier can travel to
FULL UP position
Primer rocker arm bolt
not properly adjusted
See adjustment procedure in this manual
Tipped primer
Case retainer out of adjustment
See adjustment procedure in this manual
Cases not aligned well due to
out of tolerance or damaged rim
Install sizing die without decapper in priming
station for better alignment.
See Changing Dies, Station #2.
Dirt or gun powder in shell holder grooves
Scrape shell holder grooves with paper clip. Use
compressed air to remove debris.
Tumbling media on primer post
or in primer feed
Remove and clean primer feed. Do not process
cases with tumbling media lodged in primer
flash hole.
Primer does not feed onto primer punch
Oil in trough
Clean oil from trough
Primer trough not full
Keep primer trough full
S
hell plate fails to index
Damaged case ejector pawl
Straighten pawl to prevent excessive
clockwise movement of shell plate
Carrier out of adjustment
See adjustment procedure
in this manual
Indexer improperly installed
See adjustment procedure
in this manual
Alignment of the Carrier to the Turret
This is an adjustment that need never be done unless
you disassemble the carrier from the ram.
The draw bolt head, at the bottom of the ram,
MUST be loosened so the carrier can be rotated on
the end of the ram. With the index flipper in the “in
position” and the carrier at the pull out rib position,
swing the carrier clockwise (viewed from top) un-
til center hub of index flipper contacts the pull-out rib.
[
FIGURE 4
]. Tighten draw bolt securely — 11.6 ft./lbs.
Troubleshooting
PULL-OUT RIB
INDEX FLIPPER
DRAW BOLT
FIGURE 4