Ledj SPECTRA PAR 7T3 Скачать руководство пользователя страница 10

DMX-512: 

• DMX (Digital Multiplex) is a universal protocol used as a form of communication between 

intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the 

controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the 

DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have 

a data “out” terminal).

DMX Linking: 

• DMX is a language allowing all makes and models of different manufactures to be linked together 

and operate from a single controller, as long as all fixtures and the controller are DMX compliant. 

To ensure proper DMX data transmission, when using several DMX fixtures try to use the 

shortest cable path possible. The order in which fixtures are connected in a DMX line does not 

influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be 

placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a 

fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to 

address 1 to that unit, no matter where it is located in the DMX chain.

DATA Cable (DMX cable) requirements (for DMX operation):

• The Spectra Par 7T3 can be controlled via DMX-512 protocol. The DMX address is set on the 

back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for 

data input/output. 

Also remember that DMX cable must be daisy chained and cannot be split.

9.

Further exterior DMX and power cables 

can be purchased from all good sound and 

lighting suppliers or Prolight dealers.

Please quote:

 

DMX:   

 

Power:

  

LEDJ141 - 1m 

LEDJ146 - 1m

 

LEDJ142 - 2m 

LEDJ147 - 2m

 

LEDJ143 - 5m  

LEDJ148 - 5m

 

LEDJ144 - 10m 

LEDJ149 - 10m

 

Interior to exterior DMX:

 

LEDJ91 - 1m

   

 Spectra Par 7T3   

 

 

 

     

          

 

                 DMX Set up

IP Rated Exterior Power Cable

IP Rated Exterior DMX Cable

Interior to IP Rated Exterior DMX Cable

Содержание SPECTRA PAR 7T3

Страница 1: ...www prolight co uk Order code LEDJ257 USER MANUAL SPECTRA PAR 7T3 IP 66...

Страница 2: ...ON TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult you...

Страница 3: ...ble is never crimped or damaged Check the equipment and the power cable periodically Avoid direct eye exposure to the light source while the product is on If the equipment is dropped or damaged discon...

Страница 4: ...ckets Power consumption 35W Power supply 100 240V 50 60Hz IP rating IP 66 Dimensions 125 x 156 x 180mm Weight 1 6Kgs Overview Setup Operating Instructions The Spectra Par 7T3 Exterior is a DMX 512 con...

Страница 5: ...h value and adjust by using the UP and DOWN buttons Speed values SP00 SP99 00 slow 99 fast Flash values FS00 FS99 00 slow 99 fast In Pr01 you can set a specific static colour When in P 01 Press the E...

Страница 6: ...ngs press the M and E button at the same time 3 channel mode DMX chart 4 channel mode DMX chart 5 Spectra Par 7T3 DMX Programme Charts Channel 1 Channel 1 2 3 Channel 1 2 3 4 Value 0 1 22 23 45 46 68...

Страница 7: ...de DMX chart 6 channel mode DMX chart 6 Spectra Par 7T3 DMX Programme Charts Channel 1 2 3 4 5 Value 0 255 0 255 0 255 0 255 0 255 Function Red 0 100 Green 0 100 Blue 0 100 Master dimmer 0 100 Strobe...

Страница 8: ...Spectra Par 7T3 DMX Programme Charts 6 channel mode DMX chart continued 7...

Страница 9: ...place setting is successful 3 Now Press the 4 button and the blue LED s will come on this now means that the second digit 4 tens place setting is successful 4 Now Press the 5 button and all of the R...

Страница 10: ...mple a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controlle...

Страница 11: ...power in put and power linking The fixture is then supplied with a short 13A to IP66 connector power cord If at any stage the 13A plug is removed please follow the chart below Any changes to the conn...

Страница 12: ...ve fixture is disturb ing the link Bad data link connection Inspect the connection and cables Correct the connection Repair or replace the damaged cables Insert a termination plug into the output sock...

Страница 13: ...problem persists Fixture is too hot The LEDs are damaged The power supply settings do not match the local AC voltage and frequency Allow the fixture to cool down Make sure that all air vents are not...

Страница 14: ...13 Notes Spectra Par 7T3 Notes...