www.prolight.co.uk
Slimline 12HEX12
User Manual
8
RGBAWUV colour mix mode:
In this mode you can set the fixture to any colour and any brightness.
To access the colour mix mode, press the
“MODE”
button on the rear of the unit to show
C1--
with 3 digits after on the LED display. Press the
“ENTER”
button to confirm.
The
C1
represents red,
C2
= green,
C3
= blue,
C4
= white,
C5
= amber,
C6
= UV and
CF0
= strobe.
The 2 digits after are the brightness setting from
00
~
99
, or the strobe speed if in
CF0
.
For example:
If you set 1, 2, 3, 4, 5 and 6 all to zero, your unit will have no LEDs lit up (blackout).
If you set
C100
to
C199
and 2, 3, 4, 5 and 6 to zero, your unit will show only red LEDs.
Press the
“ENTER”
button to confirm the setting and move to the next colour.
To exit out of any of the above options, press the
“MODE”
button.
Colour fade mode:
To access the colour fade mode press
“ENTER”
until the display shows
FA--
on the LED display.
To adjust the speed use the
“UP”
and
“DOWN”
buttons to select any value from
FA00
~
FA99
.
To select the strobe mode press
“ENTER”
, the LED display will change to
FF--
, using the
“UP”
and
“DOWN”
buttons to select any value from
FF00
~
FF99
.
Value: 00 - 99 (00 = low, 99 = high)
To exit out of any of the above options, press the
“MODE”
button.
Colour change mode:
To access the colour change mode press
“ENTER”
until
JU--
shows on the LED display. To adjust
the speed use the
“UP”
and
“DOWN”
buttons to select any value from
JA00
~
JA99
. To select the
strobe mode press
“ENTER”
, the display will change to
JF--
, using the
“UP”
and
“DOWN”
buttons
to select any value from
JF00
~
JF99
.
Value: 00 - 99 (00 = low, 99 = high)
To exit out of any of the above options, press the
“MODE”
button.
Master/slave mode:
To set the master unit, press the
“MODE”
button on the rear of the master unit then select your
desired program (sound active, auto, static colour, colour mix or one of the built-in programs).
To set the other units in slave mode, press the
“MODE”
button on the rear of the unit to show
SLAU
on the LED display and press the
“ENTER”
button to confirm the setting. The units will now run in
sequence with the master unit.
To exit out of any of the above options, press the
“MODE”
button.
Please ensure that all slave units are set to the same DMX channel mode as the master unit.
Operating instructions